CHAPTER 8
– DESCRIPTION OF INTERFACE OUTPUTS
8.1 – WELD ERROR (WRONG)
The WRONG signal identifies a wrong weld which is out of the limits set conforming to the
table shown below.
The output, which is an opto-electronic contact, closes at the beginning of the hold time and
remains closed until the end of the hold time (if the cycle start signal had already been
deactivated), as long as the start button is held down or, if present, until the end of the pause
time.
When an error message appears on the control unit, the wrong remains high until the error is
cleared from the display through the CLEAR
key or through the ERROR RESET input
(when the additional board 50200 is present).
WRONG SIGNAL ACTIVATION TABLE
WORKING MODE
-
►
CONTROL MODE
|
▼
IK / FIX / RO / VEK / PWK /
DYN
ENE
NO
/
Min time
Max time
CUR
Minimum current limit
Maximum current limit
Min time
Max time
Minimum current limit
Maximum current limit
RO
Minimum conduction limit
Maximum conduction limit
Min time
Max time
Minimum conduction limit
Maximum conduction limit
VE
Minimum secondary voltage limit
Maximum secondary voltage limit
Min time
Max time
Minimum secondary voltage limit
Maximum secondary voltage limit
PW
Minimum power limit
Maximum power limit
Min time
Max time
Minimum power limit
Maximum power limit
ENE
Minimum supplied energy limit
Maximum supplied energy limit
/
QUALITY-T
|
▼
THICK
Minimum material initial thickness limit
Maximum material initial thickness limit
Min time
Max time
Minimum material initial thickness limit
Maximum material initial thickness
limit
IDENT
Minimum final indentation limit
Maximum final indentation limit
Min
time
Max
time
Minimum final indentation limit
107/128