22
TEC-67231-2 Technical description Prizrak-8xx BT
16
X2
(6-pin)
Output №1 (+)
1 – 59
50 (5) — АСС (remote start)
17
Output №2 (+)
1 – 59 50 (6) — IGN 2 (remote start)
18
Output №3 (+)
1 – 59 50 (3) — starter motor (remote start)
19
Output №4 (-)
1 – 59 50 (2) — key is in ignition switch (remote start)
20
Output №5 (+)
1 – 59 50 (4) — IGN (remote start)
21
Output №6 (-)
1 – 59 50 (1) — a third-party immobilizer bybass module power source (remote start)
22
X3
(8-pin)
Input №1 (-)
1 – 33 16 – trunk
23
Input №2 (-)
1 – 33 28 – other doors
24
Input №3 (-)
1 – 33 13 – parking brake
25
Input №4 (+)
1 – 33 7 – alarm panic override when trunk lid releasing
26
Outputs №5 and №6
DATA1 (RX)
DATA1 (TX)
1 – 4
1 — a third party keyless bypass module control (default value); 2 — LIN; 3 — Fortin or iDataLink
bypass modules control; 4 — integrated keyless bypass module «TEC» for Toyota/Lexus (IMO,
IMI data bus, refer to the integrator)
Table 8. Programmable outputs features
№
Feature name
Feature description
0
The output is not used
There is no voltage potential
1
«Armed» status
A constant level potential is generated while in «Armed» mode
2
Pulse when «Arming»
A pulse of 0,8 sec. is formed right after arming the alarm; when AntiHiJack is triggered
3
Pulse when «Disarming»
A pulse of 0,8 sec. is formed when disarming the alarm
4
Pulse right after vehicle’s
owner authentication
A pulse of 0,8 sec. is formed right after authentication
5
Vehicle’s OEM alarm panic
status
The ouput generrates a constant level signal after triggering the vehicle’s original security system (if
equipped)
6
Panic to a pager
The output genarates a constant signal during 30 seconds after violating the vehicle’s perimeter (doors,
hood, trunk) or triggering any sensor oa the alaem
7
Panic/warning pulses to
vehicel’s klaxon
A pulse signal is formed during 30 sec. if while in armed mode the vehicle’s perimeter is violated (door/s
opened, hood, trunk; when arming/disarming). The feature may be implemented on vehicle’s without
OEM alarm system. The potential disappears right after disarming the alarm. Is used when connecting
to the vehicle’s klaxon
8
Doors, hood and trunk
A constant signal is formed when a pre-programmed door, hood or trunk is opened
9
–
–
10
Vehicle’s OEM button
pressure
A constant level signal is formed while any pre-programmed button is being pressed
11
Ignition
A constant signal is formed when the ignition is on (and when the engine is started)
12
АСС
A constant level signal is formed while the vehicle ACC is ON (the first key position of the ignition switch
can match with ignition)
13
The engine is running
A constant signal is formed while the engine running
14
Engine RPM
A pulse signal is formed with frequency of 1 pulse per second that is proportional to 20 revolutions per
minute of the crankshaft. The reflected RPM are approximate, not precised
15
Gear lever position
A constant signal is formed if the gear lever is shifted to a programmed position: for AT
transmission — R, N, D; for manual transmission-only R
*
16
The vehicle is moving
A constant level signal is formed if vehicle’s speed exceeds a certain threshold value (it is different for
each vehicle, and is in range of 5 10 km/h)
17
Front parking sensors
control (power supply)
A constant level signal is formed according to a pre-programmed algorithm for parking distance control
operation
18
Reare parking sensors
control (power supply)
19
Vehicle’s speed
A pulse signal is formed with frequency of 1 pulse per second which is proportional to vehicle’s speed
of 1 km/h. The reflected speed is approximate, not precised
20
Brake
A constant level signal is formed when the brake pedal is applied
21
Parking brake
A constant level signal is formed while the parking brake is engaged
22
Parking (marker) lights
A constant level signal is formed while the marker lights are ON
23
Timer channel («Comfort»)
A constant level signal is generated during a pre-selected time (10-60 sec.) after arming the alarm. The
time may be set up by intervals of 10 sec.
24
Starter or OBDII diagnostics
bus blocking (NC relay
control)
A constant level signal is generated: while the CAN-bus is active prior to authentication and also when
AntiHiJack is triggered
25
Pulse for hood lock latching
A pulse signal is formed duiring 0,8 sec.: after vehicle arming; when immobilizer, AntiHiJack is triggered.
The signal is not formed if the hood is being open
26
Parking distance control LED
indicator output
Is used for parking distance system status indication. If the operation algorithm is «Activation by reverse
gear» or «Activation by reverse gear with switch off priority» — the LED glows when the parking sensors
are activated. If the algorithm is «Activation by speed» — the LED glows when the sensors are deactivated
27
Aftermarket parking heater
control
Assign this feature to any programmable output in order to control the engine heater in the «analog» way.
To display the status of engine heater in the app, assign to any programmable input the feature «Engine
heater status»