33
TEC-67231-2 Technical description Prizrak-8xx BT
12
Input/output №5 (white/’black) operation adjustment
2
Select the value 3 in thew option №11.
Assign any of the 1-59/1-33 features
13 HCU-230 integrated accelerometer sensitivity
adjustment
4
1 — minimum;....8 — maximum
14 Siren/klaxon control (on any of the outputs)
1
1 — siren; 2 — klaxon control
Programming sequence
1
Switch the ignition to the ON position.
2
Complete authentication procedure;
3
Within 10 seconds press the programming button 20 times, the alarm will indicate that the correct menu has been successfully entered
by emitting 10 beeps and LED flashes.
4
Select a desired option by pressing and releasing the programming button the number of times corresponding to the option number. The
alarm will indicate the selected option number by a series of beeps and LED flashes.
5
Select a desired option value by pressing and holding the brake pedal, The alarm will indicate the current option value by a series of
beeps and LED flashes., the beeps length will change.
6
Still holding the brake pedal, select a desired option value by pressing and releasing the programming button the number of times
required to advance from the current option value to a desired one. The alarm will indicate the new option value by a series of beeps
and LED flashes. Keep in mind that after the last option value number goes the first one. After releasing the brake pedal and turning the
ignition to the OFF position, the alarm will exit the programming mode saving the settings in the nonvolatile memory. Do not allow more
than 10 seconds to lapse between steps when the brake pedal is not pressed or the program mode will be automatically exited and you
will have to start over.
Registering the hood compartment module HCU-230/BT module
Registration is the «pairing» procedure of the HCU-230 module with the main alarm module.
The registration is carried out on a PC via the TECprog2 software or with the programming button by entering the special programming menu.
The hood compartment module will not work with another main alarm module after registration is complete until registration of the HCU-230
is voided (refer to the chapter «Cancelling registration of the HCU-230/BT module».
HCU-230/BT module registration via TECprog2
1
Install the main alarm module and the hood compartment module on a vehicle and 12 V to both modules.
2
Launch the TECprog2 software, plug in the alarm via mini USB-cable or connect to the alarm via Bluetooth (using the special TECprog
USB bluetooth adapter) and follow the instructions.
The registration procedure may be completed without installing the modules on a vehicle, it can be done on the table, however, the modules
must be supplied with +12 V.
Registering the module by using the programming button and the special programming menu
The registration procedure is available only during the first 2 minutes after power has been supplied to the HCU module.
1
Install the main alarm module and the HCU on a vehicle and supply power to both modules.
2
Turn the vehicle’s ignition ON and complete an authentication procedure (enter PIN code and/or wait until the radio tag is detected) -
confirmation trill will sound.
3
Enter the menu «Hood compartment unit HCU-230/BT settings» within 10 seconds after authentication is complete by pressing and
releasing the programming button 20 times. The system will emit 11 beeps and flash the LED 11 times to confirm that the menu has
been successfully entered.
4
Select the option
№1
«Registering the hood compartment unit HCU-230/BT» by pressing and releasing the programming button 1 time.
The alarm will indicate the selected option number by a repeated single beep and one LED flash.
5
Press and hold the brake pedal. The alarm will indicate if any hood compartment module is already registered into the main alarm
module: one beep and one LED flash — an HCU module has already been registered; silence — no module registered.
If a module has already been registered into the main alarm unit and another (new) module is being registered then the previously registered
module will be erased from the alarm’s memory. The alarm will be working with only the newly registered HCU-230/BT module.
6
In order to register the new module press the programming button 1 time. The alarm will begin searching. There will be an intermittent
sound during the search:
•
if the alarm has detected one available module for «pairing» — the registration procedure will start immediately, herewith the beeps
length will change.
•
if the alarm has detected two or more available modules — a long beep will sound. The registration process will terminate and the beeps
length will change. Turn the vehicle’s ignition OFF and wait for at least two minutes then start the procedure all over again.
7
Successful registration is followed by the confirmation trill and a short single repeated beep indicating that one module has been
registered.
8
Release the brake pedal and switch the ignition OFF. The confirmation trill will sound.
Cancelling registration of the HCU-230/BT module
The procedure may be useful in case if the already installed module should be paired with another (new) alarm unit. After the «Cancelling
registration of the HCU-230/BT module» procedure has been completed, it is possible to re-register the module into another alarm unit.
If HCU module registration is voided, the other pre-set settings will not be reset to default settings. In order to reset the module to default
settings-perform the «Resetting to default settings» procedure.
There are three ways to reset the module.
1st way. By using the TECprog2
Run the TECprog2 software, plug in the alarm via mini USB-cable or connect to the alarm via Bluetooth (using the special TECprog USB
bluetooth adapter) and follow the instructions.
2nd way. Without the main Prizrak alarm module
1
Unpower the module.
2
Connect the input/output
№2
and
Input/output №5
to the vehicle’s ground.