30
TEC-67231-2 Technical description Prizrak-8xx BT
35 «Turbotimer» feature engaging
1 – 2
2
1 — after shifting the gear lever to «P» (Parking) and
parking brake engaging; 2 — After shifting the gear lever
to «P».
For vehicels with mechanical transmission (MT) the
«Turbo-timer» freature is engaged if only the «Safe
neutral procedure» will be completed.
36 Parking brake ignoring during remote
engine start mode
1 – 3
2
1 – Parking brake is ignored prior to remote start;
2 – Parking brake inhibits remote start; 3 – Parking
brake is ignored during entire remote start mode cycle
37 Speed ingoring when the engine is being remote
started
1 – 3
2
1 – Speed data is ignored when the vehicle is being
remote started; 2 – Speed data inhibits remote start;
3 – Speed data is ignored during the entire remote start
mode cycle
*
The value may automatically change for a specific vehicle (refer to the Integrator).
Programming sequence
1
Turn the ignition ON.
2
Complete an authentication procedure.
3
Within 10 sec. after authentication is completed press the PB 16 times, the alarm will emit 7 beeps and LED flashes.
4
Select the required option by pressing the PB the number of times corresponding to the desired option number. The alarm will indicate
the selected option number by series of beeps and LED flashes:
•
the option №10 indication – one long beep.
•
the option №11 indication – 1 long beep, 1 second pause, 1 short beep.
5
Now it is possible to change the option value by pressing and holding the brake pedal. The alarm will inform about the current option
value by series of beeps and LED flashes.
6
Change the option value by pressing the PB a number of times required to shift from the current value to a desired one. The alarm will
inform about the new option value by series of beeps and LED flashes. Keep in mind while shifting within the option, that after the last
option value goes the first one.
The alarm will automatically exit the programming mode and will save all current setting in nonvolatile internal memory after the ignition
is turned off with brake pedal released or it will also exit the menu in 10 seconds after the last action is made in the menu and if brake pedal is
not applied.
Table 13. Built-in keyless immobilizer bypass module parameters adjustment
№
Option name
Values
range
Default
value
Description
1 Keyless bypass module control protocol
1 – 3
–
1– Fortin; 2 – iDataLink; 3 – «TEC electronics»
2 Syncing with OEM immobiliser
1 – 4
–
1 – Sync complete; 2 – Sync not complete; 3 – Start the sync;
4 – Sync not possible
3 Keyless bypass «TEC-electronics» connection
method (OEM immobiliser type)
–
–
Is adjusted automatically. Can be set up manually if needed
4 OEM alarm system operating mode (remote start)
1 – 3
–
1 – OEM alarm operates in standart mode: 2 – OEM alarm is
disabled. The OEM alarm system will not «arm»; 3 – «Disarming»
and «Arming» the OEM alarm system prior to remote engine start
Programming sequence
1
Turn ignition ON.
2
Complete the authentication procedure.
If the vehicle hasn’t covered 10 km after the alarm installation and the default PIN code is not changed, then it is possible to use the default
PIN code — «2» by pressing the built-in PB twice.
3
Within 10 sec. after authentication is completed press the PB 18 times, the alarm will emit 9 beeps and LED flashes.
4
Select the required option by pressing the PB the number of times corresponding to a desired option number. The alarm will indicate the
selected option number by series of beeps and LED flashes.
5
Now it is possible to change the option value by pressing and holding the brake pedal. The alarm will inform about the current option
value by series of beeps and LED flashes.
6
Change the option value by pressing the PB a number of times required to advance from the current value to a desired one. The alarm
will inform about the new option value by series of beeps and LED flashes. Keep in mind while shifting within the option, that after the
last option value goes the first one.
The alarm will automatically exit the programming mode and will save all current setting in nonvolatile internal memory after the ignition
is turned off with brake pedal released or it will also exit the menu in 10 seconds after the last action is made in the menu and if brake pedal is
not applied.
Syncing procedure with vehicle’s original immobilizer
1
Turn the ignition ON.
2
Complete an authentication procedure.
If the vehicle hasn’t covered 10 km after the installation and the default PIN code is not changed, then it is possible to use the default
PIN code — «2» by pressing the built-in PB twice.
3
Within 10 sec. after the authentication press the PB 18 times, the alarm will emit 9 beeps and LED flashes.
4
Select the option
№2
«Sync with OEM immobiliser» by pressing the PB twice. The alarm will emit series of 2 beeps and LED flashes.
5
Now it is possible to change the option value by pressing and holding the brake pedal. The alarm will inform about the current option
value by 2 beeps and LED flashes (the factory value of this option is «2-sync not completed»).
6
Select the value
№3
«Start the sync» by pressing the PB 1 time (once). The alarm will inform about the new option value by series of 3
beeps and LED flashes. Release the brake pedal.
7
Turn the ignition OFF. The alarm will continue emitting series of 3 beeps and LED flashes.
8
Turn ignition ON — trill will sound. The alarm will now automatically exit the programming menu.