TEC-67231-2 Technical description Prizrak-8xx BT
3
Supply power to the module.
4
Disconnect the input/output
№2
and
Input/output №5
from the vehicle’s ground.
5
Within the next 10 seconds supply 5
negative pulses to the module input/output №2 and Input/output №5.
3rd way. Resetting the module to default settings using the programming button and the special programming menu
The HCU module and the main alarm unit must be installed on a vehicle and supplied with power.
1
Turn the vehicle’s ignition ON and complete an authentication procedure (enter PIN code and/or wait until the radio tag is detected) —
confirmation trill will sound.
2
Enter the menu «Hood compartment unit HCU-230/BT settings» within 10 seconds after authentication is complete by pressing and
releasing the programming button 20 times. The system will emit 11 beeps and flash the LED 11 times to confirm that the menu has
been successfully entered.
3
Select the option
№3
«Hood compartment unit HCU-230/BT registration» by pressing and releasing the programming button 3 times.
The alarm will indicate the selected option number by a series of 3 beeps and 3 LED flashes.
4
Press and hold the brake pedal. The alarm will indicate if any hood compartment module is already registered into the main alarm
module:
•
one beep and one LED flash — an HCU module has already been registered;
•
silence-no module registered.
5
Press the programming button 1 time, the alarm will inform about the start of the cancellation process process by short intermittent
beeps.
6
6. The confirmation beep will sound if the registration is successfully voided. Hereafter you may exit the programming menu by switching
the vehicle’s ignition OFF.
The system emits a long warning beep if an error occurs while cancelling the module registration. You will have to start over.
Customizing the user features
Menu 2. User settings
№
Option name
Default
values
ON
OFF
LED
Number of
beeps
LED
Number of beeps
1 Immobilizer
ON
ON
1
OFF
2
2 AntiHiJack
3 Travel distance before AntiHiJack triggers
1
Values range from 1 to 10; 1 - 100 meters; ....... 10 - 1000 meters.
Set up the distance for immobilizing the vehicle
4 Siren operation after the alert has triggered
4
Values range 1 to 4: 1 — seren OFF; 2 — siren doesn’t sound when
warning is triggered; 3 — loudness for warning is the same as
for arming/disarming (refer to the option №11); 4 — siren is ON
(maximum laudness)
5 Radio tag search sonic indication for disarming
confirmtion
ON
ON
1
OFF
2
6 Sonic confirmation after authentication and radio tag
detection when disarming
7 «Service/Valet» mode automatic deactivation
8 CDL latching when driving off
OFF
9 CDL unlatching when the ignition is turned off
10 Windows, side mirrors, sunroof automatic closure
(«Comfort»)
4
Values range from 1 to 5 : 1 — Windows closure; 2 — windows and
side mirrors closure; 3 — windows and sunroof closure; 4 — windows,
sunroof, side morrors closure; 5 — OFF (closure is not performed)
11 Siren chirps loudness when arming/disarming
4
Values range from 1 to 4: 1 — silent arming/disarming; 2 — minimum
loudness; 3 — medium; 4 — maximum
12 Authentication method (PUK code required)
1/3
Values range from 1 to 4: 1 — Radio tag; 2 — PIN code; 3 — Radio-tag
or PIN code; 4 — Radio-tag and PIN code.
•
By default the authentication method for Prizrak-810/BT
and Prizrak 820/BT is the method №3 (radio-tag or PIN code).
Once an optional Radio-tag is registered into the system — it
starts working right away and no additional settings required.
•
It is not possible to select the authentication methods №№
4 and 1 Prizrak-810/BT and Prizrak 820/BT before a radio-
tag is registered.
13 Over speeding alert
4
Values range from 1 to 10: 1 — over speeding is not monitored; 2 —
110 km/h; ...4 — 130 km/h; ... 10 — 190 km/h.
Allows to adjust the speed value for over speeding alert which will be
sent to the alarm user
14 New radio-tags registration
–
Range from 0 to 8
15 Radio-tags detection quality test
Allows to determine zones inside and outside the vehicle where radio tags are
best detected
16 AntiHiJack feature automatic deactivation with a tag
OFF
1 – ON
2 – OFF
17 Automatic rearming
OFF
1 – ON
2 – OFF
Programming sequence
1
Turn the vehicle’s ignition ON.
2
Complete authentication;
3
Within 10 sec. after the authentication enter the corresponding programming menu by pressing and releasing the programming button
12 times (or the integrated Key-ID button). The alarm will emit 4 short beeps to confirm that everything has been done correctly.