Go to the Diag
Diag
Diag
Diag option in the ACU menu to view the options for the Self Test.
Highlight the Test
Test
Test
Test option and press the *
**
* key to initiate the self-test. The
controller emits a single bleep from the sounder indicating that the controller has
run the Self Test function. If no faults are found then the screen opposite will be
displayed.
Should an issue be found then the appropriate error codes will be displayed. A
list of the possible codes is shown in the table below.
Error Code
Error Code
Error Code
Error Code
Description
Description
Description
Description
1
There is an issue with the read-write functionality of
the flash memory.
2
The input voltage for the SOLOgarde controller was
found to be out-of-range
3
The on-board regulated supply voltage was found to
be out-of-range
4
An alarm condition has occurred
5
An error was found in the memory of the controller
6
An issue was found with the boot load application of
the firmware.
In the example opposite, problems were found in the areas input voltage and the
memory of the controller.
Please refer to the troubleshooting guide in Appendix 2 for possible causes and
solutions for any errors found.
Once the test has been run, the errors are retained until such time as they are
cleared. To clear the errors, highlight the Clear
Clear
Clear
Clear option in the Diag
Diag
Diag
Diag menu and
press the *
**
* key. The controller emits a single bleep to indicate that the logged
error codes have been cleared from the controller memory and OK
OK
OK
OK is displayed on
the hand-held programmer display.
OK
Err Code
25
Err Code
- - - - - - - -
Test
Clear