188
d. “ ” Not responding
There is a detailed description of PKE functions in the driver's manual, including the method of emergency starting the vehicle
when the sensor key is exhausted, and the specific meaning of the buzzer sound.
No response
when
unlocking
The sensor key is
too far away
Whether the
sensor key has
sufficient power
Y
Bring the
induction key
close to
N
Replace the battery, the
model is CR1225
N
Disassemble the right
auxiliary switch and
short-circuit the
unlocking switch wire
Y
Y
Right auxiliary
switch failure
N
Fill in the quality
feedback form and
assist in the
investigation by
the engineer
4.3Left hand handle auxiliary switch
Left hand
handle
Auxiliary
switch
N
Left hand handle
Auxiliary switch
failure
No response when
pressing MOD
Remove the auxiliary
switch and short the
button switch line
Y
No response when
pressing SET
N
Troubleshoot
cable or
instrument failures
The windshield
cannot be raised
or lowered by
pressing the
windshield button
Whether it is normal
to push or pull the
windshield rocker
arm by hand
Y
Check the
windshield motor
or motor controller
4.4 Horn
Caution:
●There should be more than 5 seconds interval when adjusting or
checking the horn. Continuous sounding may cause ablation of the
internal coil of the horn.
●The
horn is a riveted structure, which is difficult to restore after
disassembly.
●It is prohibited to adjust the bracket nut③
.
a. If the horn switch does not respond, please refer to the
troubleshooting process of the left-hand switch on the next page
b. The speaker sounds abnormal
If the sound is small, hoarse, etc., first confirm whether the battery is
sufficient, and turn on the headlights to determine whether the battery is
sufficient according to the brightness of the light. It is normal to start the
engine and raise the speed, but abnormal low speed can also be judged as
insufficient battery power. The battery needs to be charged.
If the power is sufficient, check whether the horn adjustment bolts
①
and nuts
②
are loose. If they are loose, tighten them and check again. If
the fault cannot be eliminated after tightening, try to loosen the nut
②
and then use a Phillips screwdriver to fine-tune the bolt
①
. If the horn
does not sound, turn it counterclockwise about 270 degrees, if it is hoarse,
turn it clockwise until the sound is normal; tighten the nut
②
after the
sound is normal. If the fault persists, it is judged that the horn is faulty and
needs to be replaced.
Summary of Contents for ZONTES 310T-M 2022
Page 1: ...1 188 ZT125 310T M Maintenance Manual 2022 09 14 ...
Page 91: ...91 188 l So far the adjustment operation of the valve clearance is completed ...
Page 115: ...115 188 Electrical schematic diagram of EFI system ...
Page 156: ...156 188 Exploded view of front fork components M125 310 Directional exploded view ...
Page 173: ...173 188 ...