82
Troubleshooting
McDonald's Intelligap Grills
120418
Motor/Platen Troubleshooting
IMPORTANT!
The following visual observations do
not necessarily mean a motor has failed:
S
Oil residue on the motor housing or oil spots
are visible on the insulation.
S
The motor is making a chattering noise.
S
The front motor appears slower when
autoleveling. Swap the front motor with
either the left or right rear motors.
Reference Service Bulletin 0182SG.
All troubleshooting procedures should be followed to
determine if a motor has failed before replacing the
motor.
Note:
When completing the Return Material Tag
(RMT) for a failed motor, indicate the platen position
(left, center, right), motor location (left, right, front),
and the type of failure (mechanical or electrical).
Test 1: Visual Inspection
IMPORTANT!
Before performing this inspection,
verify that the interlock switch is OFF. Remove the
platen cover and perform a visual inspection. Check
for:
S
Grease shields binding.
S
Carbon buildup around the grease shields.
S
Wire harnesses showing damage or binding.
S
Lift cables are kinked, broken or not in the
pulley groove.
Test 2: Pulley Oscillation
Perform this test only if display reads “Please
Wait for Auto Leveling”.
IMPORTANT!
Verify that the power is ON.
Autolevel the platen. Observe the pulleys and
cables once the platen has lowered to the cook
surface.
If the pulleys do not oscillate and the cables remain
slack, set meter to DC Voltage and check pins 4, 5,
and 6 on each motor plug to ground. If all readings
fluctuate continuously, replace the motor.
Note:
Readings on good motors will stabilize
(example: 4.9, 0, 4.9).
If the platen does not lower, proceed to test 3.
Summary of Contents for C832
Page 2: ......
Page 27: ...21 McDonald s Intelligap Grills Controls and Systems Control Overview Figure 12 ...
Page 95: ...89 McDonald s Intelligap Grills Troubleshooting 8 Phase Test Motor 2 9 Phase Test Motor 3 ...
Page 97: ...91 McDonald s Intelligap Grills Troubleshooting 130925 Probe Open Troubleshooting Chart ...
Page 98: ...92 Troubleshooting McDonald s Intelligap Grills 130925 Probe Fail Troubleshooting Chart ...
Page 102: ...96 Troubleshooting McDonald s Intelligap Grills Notes ...
Page 105: ...99 McDonald s Intelligap Grills Parts Notes ...
Page 106: ...100 Parts McDonald s Intelligap Grills C832 Exploded View Figure 55 ...
Page 108: ...102 Parts McDonald s Intelligap Grills C834 Exploded View Figure 56 ...
Page 110: ...104 Parts McDonald s Intelligap Grills 150721 C835 Exploded View Figure 57 ...
Page 112: ...106 Parts McDonald s Intelligap Grills 140423 C836 Exploded View Figure 58 ...
Page 114: ...108 Parts McDonald s Intelligap Grills 150218 C838 Exploded View Figure 59 ...
Page 116: ...110 Parts McDonald s Intelligap Grills 150721 C842 Exploded View Figure 60 ...
Page 118: ...112 Parts McDonald s Intelligap Grills C844 Exploded View Figure 61 ...
Page 120: ...114 Parts McDonald s Intelligap Grills 150721 C845 Exploded View Figure 62 ...
Page 122: ...116 Parts McDonald s Intelligap Grills Control A Box X72514 12 C832 60 Hz Figure 63 ...
Page 124: ...118 Parts McDonald s Intelligap Grills Control A Box X72514 40 C832 50 Hz Figure 64 ...
Page 126: ...120 Parts McDonald s Intelligap Grills Control A Box X73133 12 C835 60 Hz Figure 65 ...
Page 128: ...122 Parts McDonald s Intelligap Grills Control A Box X73133 40 C835 50 Hz Figure 66 ...
Page 136: ...130 Parts McDonald s Intelligap Grills Control A Upper X73384 12 C845 60 Hz Figure 73 ...
Page 138: ...132 Parts McDonald s Intelligap Grills Control A Upper X73696 40 C845 50 Hz Figure 74 ...