Terminal board M5 ( FT1 - FT2 - FT3- + )
FT3 = TRANSMITTER 3 input ( BLACK WIRE)
FT2 = TRANSMITTER 2 input ( BLACK WIRE)
FT1 = TRANSMITTER 1 input ( BLACK WIRE)
+ =
POWER SUPPLY FOR ALL THE TRANSMITTERS (BLUE WIRES)
FT3
FT2
FT1
+
M5
FR3
FR2
FR1
VCC
GND
M6
Terminal board M6 ( FR1 - FR2 - FR3- VCC - GND )
FR3 = RECEIVER 3 input (BROWN WIRE)
FR2 = RECEIVER 2 input (BROWN WIRE)
FR1 = RECEIVER 1 input (BROWN WIRE)
VCC =
( + ) POWER SUPPLY FOR ALL THE RECEIVERS (BLUE WIRES)
GND =
( - ) POWER SUPPLY FOR ALL THE RECEIVERS (BLACK WIRES)
MIN
SENSITIVITY
MAX
SENSITIVITY
DIP SWITCH SW1
L1 L2 L3
SENSITIVITY ADJUSTMENT
Once the pohotocells have been positioned, their sensitivity must be regulated
by means of the potentiometer on the board. Proceed in the following way:
1) Calibrate the potentiometer depending on the distance between the
photocells (see fi gure alongside).
2) If the leds on the phtocells are off, their sensitivity is correct.
3) If the leds are on, slowly turn the potentiometer towards its maximum setting
until the leds go out.
4) Check to make sure that the relative leds come on by breaking the infrared
beam of the photocells.
POTENZIOMETRO
AL MINIMO
fi no a 2 metri
POTENZIOMETRO
A METÀ
da 2 a 4 metri
POTENZIOMETRO
AL MASSIMO
da 4 a 6 metri
13) SWING DOOR WITH TWO WINGS
If one of the door wings overlaps the other during the closing phase, the actuator confi gured as the MASTER should be applied to the
wing that overlaps the other (i.e. the wing that is the fi rst to open and the last to close).
A door with two wings can be controlled by using two BRINK actuators.
Carefully consult the drawings in the “MECHANICAL SECTION” at the beginning of this manual in order to establish the fi xing dimensions,
opening direction of the wing and the maximum weight allowed by the wing length. The system comprises a main control unit, which must
be confi gured as the MASTER and whose task is to handle the general operation of the door, and a second control unit confi gured as the
SLAVE, which receives orders and information from the MASTER.
ELECTRONIC SECTION