General Description

The ClearPath Spectrum Wireless System is comprised of 

two devices; a Coordinator (S-COR) that functions in a 

similar role as traditional wireless system receivers, and 

a Transceiver (S-TRX) that functions in a similar role as 

traditional wireless transmitters, but this is where the 

similarities end.  The Spectrum Wireless System provides 

several industry firsts:

•  Digital  two-way  communication  allows  for  greater 

security  and  ensures  successful  signal  transmission 

between devices.

•  LCD screen (S-COR) for quick and easy programming.

•  Upon switch activation, the Transceivers communicate 

valuable  information  that  is  displayed  on  the  LCD 

screen including: device ID, signal strength and battery 

monitoring.

•  Pairing of multiple Transceivers with Coordinators.

•  Two built-in outputs (S-COR).

•  3 year battery life (S-TRX).
ClearPath Spectrum products operate at 2.4 GHz, making 

the  wave  length  more  than  5  times  shorter  than 

commonly-used  frequencies.    Shorter  waves  pass 

through cracks and barriers easier, and transceivers will 

continue to attempt to contact the Coordinator until it 

receives an acknowledgement.

Section 2

Basic Installation

The S-COR is typically installed inside the door operator 

housing  area  (header  box),  since  the  power  supply  and 

operator control are located there.  

 

NOTICE:    

For proper operation, it is important to 

 

ensure that the antenna for the S-COR is located 

 

outside the operator housing. This can be 

 

accomplished by drilling a ⅜” to ½” hole in the 

 

housing and carefully pulling the antenna through. 

 

Please do not alter or modify the antenna for the 

 

S-COR in any way.

Section 3

Technical Data

Model.................................. ClearPath Spectrum™ S-COR

Input Power......................... 12-24V AC or DC

Output Contacts.................. Form C

Relay 1 Contact Rating....... 3A:24V AC

Relay 2 Contact Rating....... 1A:24V AC

Temperature Rating........... -22°F to 158°F 

 

(-30°C to 70°C)

Weight................................. 0.25 lbs.

Physical Size....................... 3 3/4"L x 2 1/4"W x 1"H

 

NOTICE:    

This device complies with Part 15 of the 

 

FCC rules.  Operation of this device is subject to the 

 

following two conditions: 1) This device may not cause

 

harmful interference and 2) This device must accept 

 

any interference received, including interference that 

 

may cause undesired operation.  Any changes or 

 

modifications not expressly approved by MS SEDCO 

 

could void the user's authority to operate this 

 

equipment.

!

Spectrum Coordinator 

INSTALLATION INSTRUCTIONS

!

!

           S-COR

h

ClearPat

NOTE: 

 Output 1 will typically be used to trigger an electronic locking device, while Output 2 will be used

to activate an automatic door.

FIGURE 1

Wiring Diagram

 

NOTE:  

To reset S-COR to

 

factory settings, press and 

 

hold < and > buttons upon

 

power up.

!

Summary of Contents for CleraPath Spectrum S-COR

Page 1: ...Basic Installation The S COR is typically installed inside the door operator housing area header box since the power supply and operator control are located there NOTICE For proper operation it is important to ensure that the antenna for the S COR is located outside the operator housing This can be accomplished by drilling a to hole in the housing and carefully pulling the antenna through Please d...

Page 2: ...itional features into the device Five additional settings are available HH Signal Range Output Delay SecureActivation Ratchet Relay and Unpair Devices These are covered below Output Delay This controls the delay time between output relays 1 and 2 and can be adjusted via the arrow keys Remember Output 1 is typically the locking device and Output 2 is typically an automatic door After adjusting time...

Page 3: ...d held The functions of these locations are described below Outside will cause the exterior opening to activate then the interior opening Inside will cause the interior opening to activate then the exterior opening Vest Inside will only activate the interior opening Vest Outside will only activate the exterior opening Vest Both and HH will activate both openings simultaneously Secondary is for seq...

Page 4: ...sed until a second signal is received NOTICE Connect device to be used in ratchet mode to Output 2 HH Signal Range ClearPath Spectrum devices transmit a much greater distance than other wireless products used in the automatic door industry Since a hand held Transceiver is paired with multiple Coordinators in a build ing or with two buildings in closer proximity the default HH Signal Range is set t...

Page 5: ...ferent channel for better performance when two openings are in close proximity this can be accomplished by using the arrow keys Note that in manual mode the current channel selection will be indicated with an asterisk then press Select The next screen will read Add Setting This is the place where users can program additional features into the device Two additional settings on the Secondary Coordi ...

Reviews: