All Transceivers (S-TRX) pair to the Primary Coordinator (S-COR) only.
The Secondary Coordinator (S-COR) must pair with the Primary Coordinator (S-COR) for vestibule sequencing to function
properly.
7898 Zionsville Road
Indianapolis, Indiana 46268
Telephone: (317) 842-2545
www.mssedco.com
Page 4
S-CORv0917
security system. There are two choices for turning “On”
this feature, Normally Open (N.O.) and Normally Closed
(N.C.), depending on whether the circuit is normally open
or normally closed. Once programming is complete,
connect the SecureActivation 2-wire harness included to
the Normally Open (N.O.) and Common (COM) of the
security device and plug the harness into the
SecureActivation socket on the S-COR (Figure 1).
WARNING:
The Security Clearance input requires
a dry contact. Do not apply voltage!
Ratchet Relay
– If Ratchet Relay is turned on, the output
2 relay will remain closed until a second signal is received.
NOTICE:
Connect device to be used in ratchet
mode to Output 2.
HH Signal Range
– ClearPath Spectrum devices transmit
a much greater distance than other wireless products
used in the automatic door industry. Since a hand-held
Transceiver is paired with multiple Coordinators in a build-
ing, or with two buildings in closer proximity, the default HH
Signal Range is set to “Reduced”, requiring a very strong
signal for the hand-held Transceiver to operate. If a hand
-
held Transceiver will not be used with any openings
nearby, the range can be expanded to “Normal” by using
the arrow keys and pressing Select when Normal displays
on the screen.
UnPair Devices
– Transceivers can be unpaired by Type, a
Single Device (requiring the PAIR button to be pushed on
that device to unpair), or All Devices, which will unpair the
Coordinator from all Transceivers.
Spectrum Coordinator
INSTALLATION INSTRUCTIONS
S-COR
h
ClearPat
™
!
!
FIGURE 3
Typical Vestibule Installation Diagram
HAND-HELD
S-TRX-HH
VESTIBULE
SECONDARY
COORDINATOR
(S-COR)
VESTIBULE
PRIMARY
COORDINATOR
(S-COR)