6) FUNCTIONS OF DIP SWITCH S1
Select the functions by means of dip-switch S1 of the control unit or by means of the indicator light
of the selector DOORPROGB
(consult sect. 9.1 for the settings of digital selector DOORPROGB).
Selector / Control unit
DIP 1
ON = Push & Go activated. Door opened in the manual mode.
OFF = Push & Go inhibited.
DIP 2
ON = Wind stop activated. Prevents the door from opening accidentally in a draught
OFF = Wind stop inhibited.
DIP 3
ON = cyclic function activated (repeated door aopening and closing).
OFF = cyclic function inhibited.
DIP 4
ON = electro-lock output activated (see sect.8 for a description of pontentiometers TM9 & TM10 wich allow
operation with the electro-lock to be optimized).
OFF = electro-lock output inhibited.
DIP 5
ON = BRINK OPERATION: MOTORIZED OPENING,MOTORIZED CLOSING.
This function is recommended for doors that may be subjected to wind force when closing and for all
those situations in which the force of the spring alone may not be suffi cient to guarantee that the door fully
closes.
OFF = BRINKS OPERATION: MOTORIZED OPENING, SPRING CLOSING.
WARNING!!
This DIP switch must be set prior to the INITIAL SETUP described in chapter 4 of the Main manual.
DIP 6
ON = activated the initial set-up cycle (see sect.4); allows power limitation to be indicated by the buzzer.
OFF= inhibits the buzzer warning for power limitation.
DIP 7
ON = door open condition with function selector in the “||” position.
OFF = night lock condition with function selector in the “||” position.
DIP 8
ON = courtesy function for the disabled. See section 10 for a description of operation.
OFF= courtesy function inhibited.
DIP 9
ON = if the operation program NIGHT LOCK is selected, the door opens and remains open 10” before closing
again.
OFF = if the operation program NIGHT LOCK is selected, the door does not open.
In NIGHT LOCK, the door can only be opened with the EMERGENCY input.
DIP 10
ON = automatically increases the pause time if the door cannot close on account of the high fl ow of persons
OFF = constant pause time.
DIP 11 (can only be selected with digital selector DOORPROGB)
ON = work program selected by means of digital selector DOORPROGB (see sect. 9).
OFF = work program selected by means of the function selector switch (see sect. 5.1) or the manual selector DOORSELFB (see sect.
5.2).
DIP 12 (can only be selected with digital selector DOORPROGB)
ON = enables regulation of the functions (dip-switch S1) and potentiometers (from TM1 to TM5) by means of digital selector
DOORPROGB.
OFF = enables regulation of the functions (dip-switch S1) and potentiometers (from TM1 to TM5) by means of control unit LGN.
All the adjustments to dipswitch S2, potentiometers TM6, TM7, TM8, TM9, TM10 and to the TECHNICAL MENU are made by
meas of digital selector DOORPROGB alone.