BRINK Series - English
27
POTENTIOMETERS
MASTER
SLAVE
TM1 = OPENING SPEED
•
•
TM2 = CLOSING SPEED
•
•
TM3 = OPENING SAFETY SENSOR CUT-OUT DISTANCE
•
•
TM4 = PUSHING POWER LIMITATION
•
•
TM5 = HOLD TIME
•
TM6 = UPKEEP VOLTAGE ON CLOSING
•
•
TM7 = WIND STOP FORCE INTENSITY
•
•
TM8 = PUSH & GO ACTIVATION DISTANCE
•
•
TM9 = INTENSITY OF FINAL CLOSING PUSH TO LINK ELECTRO-LOCK
•
•
TM10 = POWER OF CLOSING STROKE FOR RELEASING ELECTRO-LOCK
•
•
TECHNICAL MENU
PARAMETERS
MASTER
SLAVE
1_ PUSHING FORCE AT THE BEGINNING OF THE CLOSING MANOEUVRE (only the BRINKS version)
•
•
2_ PUSHING DISTANCE AT THE BEGINNING OF THE CLOSING MANOEUVRE (only the BRINKS
version)
•
•
3_ NOT USED
4_ NOT USED
5_ END OF TRAVEL DISTANCE ON OPENING
•
•
6_ PUSHING POWER AT END OF OPENING MANOEUVRE
•
•
7_ PUSHING POWER AT END OF CLOSING MANOEUVRE (BRINK version only)
•
•
8_ NOT USED
9_ PUSHING TIME AT END OF CLOSING MANOEUVRE (BRINK version only)
•
•
10_ SLOWING DISTANCE ON OPENING
•
•
11_ SLOWING DISTANCE ON CLOSING
•
•
12_ WIND STOP FORCE INTENSITY ON OPENING
•
•
13_ WING DELAY ON START-UP IN OPENING PHASE
•
14_ WING DELAY ON START-UP IN CLOSING PHASE
•
16) MEANINGS OF THE BUZZER SIGNALS (BEEPS)
5 BEEPS
= control unit without initial set-up (press START with function selector switch in 0 position)
Long BEEP
= control unit without initial set-up (keeping START depressed with function selector switch on I or II)
6 BEEPS
= ENCODER not operating or disconnected
1 BEEP
= programming procedure accessed via digital selector DOORPROGB
1 BEEP
= programming procedure quitted via digital selector DOORPROGB without memorizing the data
2 BEEPS
= programming procedure quitted via digital selector DOORPROGB with data memorized
1 long BEEP (5”) = initial set-up terminated.
17) TECHNICAL SPECIFICATIONS
POWER SUPPLY
/- 10%
Max. POWER EXT. ACCESSORIES
20W
TIPE OF OPERATION
Intensive use
OPERATING TEMPERATURE
-20°C / +50°C
PROTECTION DEGREE
IP22
18) ADVANCED FUNCTIONS - TECHNICAL MENU
The adjustments in the technical menu allow you to change the various door operating parameters. This is of use when the default
settings are not the optimal ones.
Digital selector DOORPROGB must be available for access to the TECHNICAL MENU.
enter the program from digital selector DOORPROGB, turn the key to the horizontal function locking position, press the two keys
e
, and keep them depressed, then turn the key back to the vertical work position.
The yellow leds will come on in sequence from left to right, showing that data are being loaded. After this, the red battery led and the
yellow led of photocell 3 will come on.
The digital selector DOORPROGB will now be operating on dip-switch 1 of switch S1, thus in the adjustment phase described in section
6.
Press the SET key 11 times to go to the end of the basic regulazione described in sect. 8 of the main instructions, i.e. the closing stroke
strength (TM10).
This situation coincides with the beginning of the TECHNICAL MENU;
Press the SET button once to access the point 1 adjustment option:
simularly to the previous adjustments, the yellow leds form a scale that indicates the value entered.
Press the
key to decrease or the
key to increase this value.
ELECTRONIC SECTION