BRINK Series - English
12
ELECTRONIC SECTION
BRINK (with motorized closing system)
BRINK-S (with spring closing system)
1)
ELECTRICAL CONNECTIONS
Fig. 1
●
TERMINAL
BOARD
M1
230 V.a.c. power supply: phase wire to terminal F, neutral wire to terminal N + ground connection.
The line is protected by the 5A fuse F1.
●
TERMINAL
BOARD
M2
Terminals 1-3-4
= connection of the FUNCTION SELECTOR switch installed on the side of the device.
central contact on common terminal 3;
contact made in position | on the AUX1 terminal
;
contact made in position || on the AUX2 terminal
;
Terminals 2-3
= N.C. input of the safety PHOTOCELL.
Activates during the closing phase and reverses the door’s direction.
Terminals 5-7
= N.C. input of the opening safety SENSOR mod. DOORSS340.
The door stops if an obstruction or person is detected, and only starts opening again when the sensor has
been released.
Terminals 6-7
= EMERGENCY N.C. input. Opens the door in any condition.
Can also operate in the stepping mode (see sect. 7).
●
TERMINAL BOARD M3
Terminals 8-11
= N.O. EXTERNAL RADAR input. Commands the door opening function.
It is excluded by the digital DOORPROGB selector in the night lockor exit only functions.
It is excluded by the manual DOORSELFB selector in the night lock or exit only functions.
Can also operate as an opening only input (see sect. 7).