BRINK Series - English
25
IMPORTANT!
The MASTER and SLAVE control units must be connected together with the mod.WR3MS wiring for communication and data
exchange purposes. Connect the two terminals at the end of the cable to the connectors marked J13 on the control units (logic
part LGN).
13.2) HOW TO INSTALL THE DEVICE
Strictly comply with the instructions given below in order to install the device in the correct way:
A) Fix the two BRINK actuators in compliance with the dimensions and wing opening direction shown in the drawings in the mechanical
section of this manual.
B)
FOR THE “BRINK-S” VERSION ONLY:
To effect the connection of the arms choose the ideal load of the spring depending on the leaf characteristics as described in the
paragraph 8.0 of the mechanical part.
C) Make the initial set-up as described in sect. 4. Proceed separately, fi rst with the actuator to be confi gured as the MASTER and then
with the SLAVE. If one of the door wings overlaps the other during the closing phase, keep the wing controlled by the MASTER
actuator open at the end of the initial set-up so as to allow the wing controlled by the SLAVE actuator to move freely during its initial
set-up.
D) Close both wings and select the functions suited to the operating mode for double-wing doors. The relative instructions are given in
the next chapter.
13.3) FUNCTIONS AND ADJUSTMENTS
After installing the device and completing the initial set-up, proceed with the adjustments by selecting the parameters required to
synchronize the system.
13.3.1) HOW TO ADJUST THE MASTER ACTUATOR
A) Connect digital selector DOORPROGB to the MASTER control unit without forgetting to fi t the LOGIC TAST module into connector
J8 of the control unit.
B) Access the programming mode via selector DOORPROGB (the procedure is explained in sect. 9.1), then go to dipswitch S2 (see sect.
7).
C) If the door wing must be delayed on starting (overlapping wings), set dipswitch 5 ON, otherwise set dipswitch 5 OFF if the wings must
both move at the same time.
D) Set dipswitch 6 OFF to confi gure the control unit as the MASTER.
E) Set dipswitch 7 ON to enable the control unit to operate in the “DOUBLE WING DOOR” mode.
F) Quit the programming function via selector DOORPROGB, memorizing the data (the procedure is described in sect. 9.1). The control
unit issues 2 beeps.
G) The control unit has now been set up to operate as MASTER for a door with two wings.
13.3.2) HOW TO ADJUST THE SLAVE ACTUATOR
A) Connect digital selector DOORPROGB to the SLAVE control unit, without forgetting to fi t the LOGIC TAST module into connector J8
of the control unit
B) Access the programming mode via selector DOORPROGB (the procedure is explained in sect. 9.1) and go to dipswitch S2 (see sect.
7).
C) Set dipswitch 6 ON to confi gure the control unit as the SLAVE.
D) Set dipswitch 7 ON to enable the control unit to operate in the “DOUBLE-WING DOOR” mode.
E) Quit the programming function via selector DOORPROGB memorizing the data (the procedure is described in sect. 9.1). The control
unit issues 2 beeps.
F) The control unit has now been set up to operate as SLAVE for a door with two wings.
13.3.3) HOW TO CHECK THE WAY THE DOOR OPERATES
After having powered the two actuators, select the required function with the dipswitches and adjust the potentiometers as described in
sect. 6, 7 and 8. Remember that some of the settings must only be made on the MASTER control unit while others must be made on
both the MASTER and SLAVE.
Carefully consult the TABLE in sect. 15, which shows, for each parameter, whether the adjustment concerns both the control
units or just the MASTER.
• If the door wings must be delayed on starting, set potentiometer TM2 (closing speed) of the MASTER control unit to a lower level
(about half) than potentiometer TM2 of the SLAVE control unit. However, the MASTER actuator will start closing at a lower speed so
that the SLAVE actuator can access the fi nal wing slowing phase without reaching the overlapping point of the wings during its travel.
If, during the closing phase, the wings should near each other below the selected delay time owing to sudden friction for example, the
direction of the wings would be reversed.
• Lastly choose the required work program with the function selector device used (mechanical selector DOORSELFB, digital selector
DOORPROGB or the simple function selector switch). Remember that this latter must be connected to the MASTER control unit.
• Now check the movement of the door by activating the opening manoeuvre and making sure that all the control and safety parts of
the device operate correctly.
To change the preset delay between the wings, use digital selector DOORPROGB and connect it to the MASTER control unit, then
access the TECHNICAL MENU (see sect. 18 TECHNICAL MENU) and modify the values in points 13 (wing delay on opening) and 14
(wing delay on closing). The hold time with the door open must only be regulated by potentiometer TM5 of the MASTER control unit.
ELECTRONIC SECTION