BRINK Series - English
15
f) Turn on the mains power again and wait for an acoustic signal (“BEEP”).
g) Set dip-switch 6 of Minidip S1 to the ON position.
h) Switch off the mains power supply (230V) for about 5 seconds.
i) Turn on the mains power again and wait for an acoustic signal (“BEEP”)
j) Set dip-switch 6 of Minidip S1 to the OFF position.
k) Switch off the mains power supply (230V) for about 5 seconds.
l) Turn on the mains power again and wait for an acoustic signal (“BEEP”)
m) Press button PS1 (START) on board CPB-1. The control unit will issue 5 beeps and will begin the spring loading manoeuvre in the
constant pressure mode (the movement will stop when the start button is released and will continue when start is pressed again).
LOCKED
n) Bring the spring load back to the standard value shown when the red mark on the
belt matches the red mark on the pulley (see fi gure alongside), then lock the spring
in this position.
o) Move the locking screw from the free position to the locked position, making sure
that it fi ts into the locking hole on the pulley.
p) !! WARNING, the INITIAL SET-UP will be cancelled after these operations and
will therefore have to be made again at the appropriate time, as described in
section 4.
4)
HOW TO SET THE DEVICE AT WORK (INITIAL SET-UP)
Before to execute the INITIAL SET-UP, set the DIP n°5 according to operation type
(see section 6)
.
After having fi xed the device to the door and loaded the spring (only for the SW version), move the wing as far as it will go by hand. Make
sure that the movement is smooth, fl uid, without friction and that it ends with the door fully against an end rabbet.
Proceed with the initialization phase (initial set-up). This operation is obligatory as it allows the control unit to acquire the stop points.
Strictly comply with the following instructions:
a) Make sure that the device is not powered and that the dip-switches of S1 are in the OFF status.
b) Move dip-switch 6 of S1 to the ON position and the FUNCTION SELECTOR switch to “|” (day functions).
c) Move dip-switch 4 of S1 to the ON position, but only if the electro-lock is installed.
d) Move dip-switch 5 of S1 to the ON position to enable, in the BRINK-S version, closing with motor push in addition to spring push.
e) Set the door to the closing status.
f) Powerthe device: the power unit gives 3 bips, the last two immediately following one another.
WARNING!
During the initial set-up, the door moves with more force than the normal operating conditions. Proceed with care and keep well
clear of the door’s operating range.
g) Press button PS1 (start input) on board CPB-1.
h)
BRINK-S version
: the door will complete a full opening cycle at slow speed.
Once this manoeuvre has terminated, a prolonged BIP will indicate that the procedure has ended.
Door closing occurs at the end of the pause time.
BRINK version
: the door will push lightly closed and will then proceed with a complete opening / closing cycle at slow speed.
Once the door has closed, a prolonged BIP will indicate that the procedure has ended.
IMPORTANT: during the initializing phase, there must be no obstructions in the manoeuvring area and the door must not be
helped along by hand.
Once the initial set-up has terminated, make an opening manoeuvre by means of a command input and check the movements according
to the default settings.
SAFETY:
The thrusting force of the door can be checked during the starting phase and at various stages of its movement by listening
to the buzzer and the indications given by the warning light
of selector DOORPROGB. The effective intensity of this thrusting
movement can be checked by obstructing the movement in order to stop the door and reverse its direction.
Potentiometer TM4 on board LGN can be used to vary the power of the door thrusting action and to accurately set the required activation
limit.
A brief signal from the buzzer during the starting up phase only, indicates that the thrusting power setting is good.
Set dip-switch 6 of S1 to the OFF position to inhibit the power limiting buzzer.
After 5 consecutive attempts to shut the door when an obstacle continuously causes the door to reverse its movement and open, the
open door pause will be automatically increased by 20 seconds until the obstacle has been removed and the door is able to complete its
closing phase.
Lastly, select the required functions, set the speed, time settings and distances to optimize the operation of the door to suit personal
requirements.
4.1) HOW TO CANCEL A PREVIOUS INITIAL SETUP
If wing travel, door weight or spring loading (only for the SW version) are changed, the initializing phase of the control unit must be
repeated.
Proceed in the following way:
1. Disconnect the power source, then set dip-switch 6 of S1 to the OFF status and power the control unit.
2. After the initial bip, set dip-switch 6 of S1 to the ON status and disconnect the power source.
3. Power the control unit, wait for the initial bip and set dip-switch 6 of S1 to the OFF status.
4. Shut off the power supply;
5. The previous initial setting will be cancelled;
6. Repeat the previous operations from point a) to point h) to enter the initial setup again.
ELECTRONIC SECTION