Tandberg Data M-Series Remote Management Card User’s Guide
71
Tape Alert
Flag
E-mail Message Error
Type
Description
4
Soft Error
Media can no longer be written or read, or performance is
severely degraded
5
Hardware Failure
The drive can no longer read data from the tape
6
Hardware Failure
The drive can no longer write data to the tape
9
Hardware Failure
Write command attempted to a write-protected tape
13
Hardware Failure
Tape snapped or cut in the drive where media can be
ejected
14
Hardware Failure
Tape snapped or cut in the drive where media cannot be
ejected
20
Soft Error
The drive has a head clog or needs cleaning
22
Soft Error
The cleaning tape has expired
30
Hardware Failure
The drive has a hardware fault that requires a reset to
recover
31
Hardware Failure
The drive has a hardware fault that requires a power cycle
to continue
33
Soft Error
Error recovery action
40
Hardware Failure
Library mechanism is having trouble communicating with
the tape drive
41
Soft Error
Stray tape left in library after previous error recovery
43
Operator Access
Library door open
44
Hardware Failure
The library mechanism had a hardware fault that is not
mechanically related
45
Hardware Failure
Library magazine not present
Summary of Contents for MSERIES RMC USER
Page 1: ...Tandberg Data M Series Remote Management Card User s Guide T6473046 01 Ver 1 Rel 0...
Page 6: ...vi Tandberg Data M Series Remote Management Card User s Guide...
Page 10: ...x Tandberg Data M Series Remote Management Card User s Guide...
Page 14: ...xiv Tandberg Data M Series Remote Management Card User s Guide...
Page 86: ...72 Tandberg Data M Series Remote Management Card User s Guide...
Page 90: ...76 Tandberg Data M Series Remote Management Card User s Guide...