Chapter 4 ALERT Library Management
Monitoring Configuration
48
Tandberg Data M-Series Remote Management Card User’s Guide
Figure 21 Monitoring
Configuration
Monitoring Interval
4
To set the monitoring interval time in minutes:
1
In the
Monitoring Interval
section of the page, type the desired
number of minutes between monitors. The monitoring
determines the polling frequency for library configuration
changes. The interval entered must be between 0 and 60
minutes.
2
Press
Apply
. A
Results
page indicates the monitoring interval
information has been saved.
3
Press
OK
to return to the
Monitoring Configuration
page.
Note:
The default monitoring value is 5 minutes. If the
monitoring interval is changed to 0 (zero), no library
configuration changes are reported, and no
configuration change e-mails are sent.