![Tandberg Data MSERIES RMC USER User Manual Download Page 81](http://html1.mh-extra.com/html/tandberg-data/mseries-rmc-user/mseries-rmc-user_user-manual_3480068081.webp)
Tandberg Data M-Series Remote Management Card User’s Guide
67
260F
Hardware Failure
The servo task has received an invalid command code
2610
Hardware Failure
The hand action ‘completed’ with no cartridge detected in the hand
2611
Soft Error
The put action ‘completed’ with the cartridge still in the hand
2614
Soft Error
Command cannot be executed without first initializing the axis
2615
Hardware Failure
Theta nvr data has been corrupted, or not yet initialized
2616
Hardware Failure
Axis friction nvr data has been corrupted, or not yet initialized
2617
Hardware Failure
Axis offset nvr data has been corrupted
2618
Hardware Failure
The build nvr data has been corrupted, or not initialized
2619
Hardware Failure
An error has been detected in the servo nvr
261B
Hardware Failure
The hand action ‘completed’ but there was a hand sensor failure
261C
Hardware Failure
The hand action ‘completed’ but was unable to engage
261D
Hardware Failure
The hand will not move in either direction
261E
Hardware Failure
The hand could not get the cartridge to its required position
261F
Hardware Failure
The elevator sensor of the box was not detected during elevator
calibration
2620
Hardware Failure
Elevator nvr data has been corrupted or not yet initialized
2621
Hardware Failure
The X axis cannot be moved properly in either direction
2622
Hardware Failure
The servo failed to raise the drive hub
2623
Hardware Failure
The cartridge is still being retained by the drive
2626
Hardware Failure
The Theta angles are out of specification after calibration attempt
2627
Hardware Failure
The X axis did not travel the minimum distance when calibrating
2628
Hardware Failure
The Y axis did not travel the minimum distance when calibrating
262A
Hardware Failure
The Theta sensor closest to the right magazine failed to switch
262B
Hardware Failure
The Theta sensor closest to the left magazine failed to switch
262C
Hardware Failure
The X axis sensor could not be detected changing state
262D
Hardware Failure
The Y axis sensor could not be detected changing state
262E
Hardware Failure
The hand axis did not travel the minimum distance when
calibrating
262F
Hardware Failure
The X axis friction is too high for normal operation
2630
Hardware Failure
The Y axis friction is too high for normal operation
2631
Hardware Failure
The Theta axis friction is too high for normal operation
2632
Hardware Failure
The hand axis friction is too high for normal operation
2633
Hardware Failure
The Z axis did not travel the minimum distance when calibrating
FSC Code
E-mail Message Error
Type
Description
Summary of Contents for MSERIES RMC USER
Page 1: ...Tandberg Data M Series Remote Management Card User s Guide T6473046 01 Ver 1 Rel 0...
Page 6: ...vi Tandberg Data M Series Remote Management Card User s Guide...
Page 10: ...x Tandberg Data M Series Remote Management Card User s Guide...
Page 14: ...xiv Tandberg Data M Series Remote Management Card User s Guide...
Page 86: ...72 Tandberg Data M Series Remote Management Card User s Guide...
Page 90: ...76 Tandberg Data M Series Remote Management Card User s Guide...