097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 175
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
BTBCKUP
BesTime backup reference disqualified
BesTime backup sources qualified
CLKBRDG
Clock entered Bridging mode
Clock exited Bridging mode
CLKFREE
Clock entered Free-run mode
Clock exited Free-run mode
CLKHOLD
Clock entered Holdover mode
Clock exited Holdover mode
CLKWARM
Clock entered Warm-up mode
Clock exited Warm-up mode
SYNTHEOR
Output generator exceeded pull-in
range
Output generator within pull-in range
GPS Codes
ANTCOMM
GPS antenna communication fault
GPS antenna comm fault cleared
GPSPOS
GPS antenna position unknown
GPS antenna position known
GPSPWR
GPS power fault
GPS power fault cleared
GPSSYS
GPS system fault
GPS system OK
GPSTRK
GPS is not tracking satellites
GPS is tracking satellites
INPDISQ
GPS input is disqualified
GPS input is enabled
INPLOS
LOS fault
LOS fault cleared
INPFRQ
Frequency threshold exceeded
Frequency within threshold
INPPHASE
Phase error exceeded threshold
Phase error within threshold
EXDSC
Excessive discontinuity fault
Excessive discontinuity cleared
FFOFF
FFOFF exceeded threshold
FFOFF within threshold
MTIE
MTIE exceeded threshold
MTIE within threshold
TPIUSIG
TPIU signal fault
TPIU signal fault cleared
PRS and INP[p] Codes
INPDISQ
Input disqualified as possible reference
Input qualified as possible reference
INPAIS
AIS fault
AIS fault cleared
INPLOS
LOS fault
LOS fault cleared
INPOOF
OOF fault
OOF fault cleared
INPFRQ
Frequency threshold exceeded
Frequency within threshold
INPPHASE
Phase error exceeded threshold
Phase error within threshold
INPQL
Quality Level (SSM) exceeded
threshold
Quality Level (SSM) within threshold
Table 6-6. Set and Clear Conditions for Alarms (Continued)
Alarm ID
Set Alarm Conditional Description
Clear Alarm Conditional Description