Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
134
TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Normal Response
TP-SSU 03-10-24 11:22:11
M
TS1000 COMPLD
"SYS,EQPT:MJ,PWRA,NSA,03-10-24 11-22-11:\"POWER A FAILED\""
"SYS,EQPT:MJ,EXPFAIL,SA,03-10-24 11-22-11:\"EXPANSION CONNECTIVITY FAILED\""
"IOC2,EQPT:MJ,CLKFREE,SA,03-10-24 11-25-15:\"CLOCK ENTERED FREE-RUN MODE\""
"INP1,T1:MN,INPLOS,NSA,03-10-24 11-25-16:\"LOS FAULT\""
"INP2,T1:MN,INPDISQ,NSA,03-10-24 11-25-17:\"INPUT DISQUALIFIED AS POSSIBLE
REFERENCE\""
"INP2,T1:MN,INPLOS,NSA,03-10-24 11-25-17:\"LOS FAULT\""
;
Displaying Alarm Status
The RTRV-COND command displays information about the current summary alarm
status of components within the TimeProvider. The active IOC reports alarms for the
Input, Output, and Expansion Panel.
RTRV-COND:[<tid>]:<aid>:[<ctag>];
This command always has an access level of USER.
Normal Response Format
<cr><lf><lf>
^^^sid^date^time<cr><lf>
M ^ctag^COMPLD<cr><lf>
^^^”SYS:<pwra>,<pwrb>,<expstatus>,<extfault>,<ioc1eqpt>,
<ioc2eqpt>,<sysqlevel>,<lastdat>,<lasttim>”<cr><lf>
^^^”IMC:<ioc1comm>,<ioc2comm>”<cr><lf>
[^^^”IOC1:<iocstatus>,<ioccomm>,<imccomm>”<cr><lf>]
[^^^”IOC2:<iocstatus>,<ioccomm>,<imccomm>”<cr><lf>]
^^^”GPS:<gpsstatus>”<cr><lf>
^^^”PRS:<prsstatus>”<cr><lf>
^^^”INP1:<inpstatus>”<cr><lf>
^^^”INP2:<inpstatus>”<cr><lf>
^^^”OUTA:<outstatus>”<cr><lf>
^^^”OUTB:<outstatus>”<cr><lf>
^^^”OUTC:<outstatus>”<cr><lf>
^^^”OUTD:<outstatus>”<cr><lf>
;
<aid>
Description
ALL (or null)
Access Identifiers