097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 173
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
FREEFLT
Indicates if the Output
Fault is issued when
the local oscillator
enters Free-Run
mode.
EQPT
SQUELCH
ON – In fault mode, generate
outputs based on system SSM
AIS – In fault mode, generate
AIS outputs
SQUELCH – In fault mode,
outputs are turned off
GPSCLR
DEL
The time, in seconds,
after a cleared GPS
fault can be used.
EQPT
5 s
0 to 1000 s
GPSFLTDEL
Time, in seconds,
before a GPS fault
indicated it is not valid
EQPT
1 second
1 to 1000 s
HOLDFLT
Indicates if the Output
Fault is issued when
the local oscillator
enters Holdover mode
EQPT
ON
ON – In fault mode, generate
outputs based on system
SSM
AIS – In fault mode, generate
AIS outputs
SQUELCH – In fault mode,
outputs are turned off
INPREF
Indicates if the system
automatically selects
another reference
input. Operator has
enabled the selected
reference input
(REFMODE must be
set to FORCED)
T1
PRS
PRS – PRS input is selected
as reference
INP1 – INP1 is selected as
reference
INP2 – INP2 is selected as
reference
LOCTIM
The local system time
offset has changed
EQPT
(00)-00
(hh) – hours offset
±
12
mm – minutes offset 00 to 59
REFMODE
Indicates if the system
reference can be
selected automatically
or by the user
EQPT
AUTO
AUTO – System uses
QLEVEL and Priority to select
the system reference
FORCED – User selects the
system reference. If the
selected reference fails, this
value reverts to AUTO mode
TIMCHG
The system time has
been changed
EQPT
hh-mm-ss
hh – hours (24-hour clock)
mm – minutes
ss – seconds
Table 6-5. Event Codes (Continued)
Event ID
Keyword
Description
AID
TYPE
Default Value/
Keyword
Description of Values