Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
170
TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
XFEROK
Transfer of the IMC
Istate to the IOC,
transfer of the IOC
Istate to the IMC, or
transfer of the IOC
Istate to the redundant
IOC was successful
EQPT
n/a
n/a
IOC Event Codes
CLKTYPE
The specified IOC
clock has been set to
the specified value.
This value is used to
define the IOCs pull-in
range and SSM
generation in Holdover
mode
EQPT
TYPEI
ST3E | TYPE I
ST2 | TYPE II
INPREF
The specified input
has been set as the
system reference
EQPT
PRS
PRS | INP1 | INP2
IOCMODE
The specified IOC has
become Active
EQPT
ACTIVE
ACTIVE | STANDBY
IOCSTATE
The specified IOC has
been inserted into the
system. The IOC is
automatically placed
In-Service
EQPT
INSRV
INSRV – In service
The specified IOC has
been taken out of
service. The IOC can
no longer generate
alarms, be
provisioned, or accept
queries
OOSRV – Out of service
Communication
between the IMC and
IOC has failed
COMMFLT –
Communications fault
The specified IOC has
been removed from
the system
UNEQUIPPED
Table 6-5. Event Codes (Continued)
Event ID
Keyword
Description
AID
TYPE
Default Value/
Keyword
Description of Values