Chapter 7 Specifications of the TimeProvider
Communications Ports
194
TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Communications Ports
Serial Ports
Two EIA-232 serial ports are available: the local Craft port and the Remote port.
Specifications are listed in
Table 7-1
.
Table 7-1. Serial Port Specifications
Specification
Factory Default
Available
Local Craft Port
Baud rate
9600
2400, 9600, 19200, 28800,
34800, 57600, 115200
Word length
8 bits
8 bits
Parity
None
None, Odd, Even
Stop bits
1
1
Echo
Off
Off, On
Software flow control
XON/XOFF
Off
Off, On
Hardware flow
control CTS/RTS
Off
Off, On
RS-232 configuration
DCE
DCE
Remote Port
Baud rate
9600
2400, 9600, 19200, 28800,
34800, 57600, 115200
Word length
8 bits
8 bits
Parity
None
None, Odd, Even
Stop bits
1
1
Echo
Off
Off, On
Software flow control
XON/XOFF
Off
Off, On
Hardware flow
control CTS/RTS
Off
Off, On
Handshake
DTR/DSR
On
On
RS-232 configuration
DTE
DTE