097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 183
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
INPQL
The received SSM on the
specified input is of lesser
quality than the local oscillator’s
QLEVEL.
T1
NSA
MN
MN
MN
INPTRR
Specified input port has a
Tip/Ring reversal on its
connection to the system.
T1
NSA
MN
MN
MN
EXDSC
Specified input port has exces-
sive discontinuities, indicated by
more than 3 signal faults of the
same time within 5 minutes.
Alarm clears when there are less
than 3 faults in a 5 minute
period.
T1
NSA
MN
MN
MN
MTIE
The specified input port has
exceeded at least 1 of the MTIE
alarm thresholds.
T1
NSA
MN
MN
MN
AID = E422A, E422B, E422C, E422D
E422
FAULT
The EIA-422 Output is not
functioning properly.
T1
NSA
NA
NA
NA
AID = RTMA[-p], RTMB[-p], RTMC[-p], RTMD[-p]
S1LOS
LOS on Side 1
T1
NSA
MN
MN
Mn
S2LOS
LOS on Side 2
T1
NSA
NA
NA
NA
EXSLIP
Excessive Slip Rate
T1
NSA
NA
NA
NA
RTM
FAULT
The Retimer module is not
functioning properly.
T1
NSA
NA
NA
NA
Table 6-7. Alarm Codes (Continued)
Event ID
Description
AID
TYPE
Service
Affecting
Alarm Level
SSU
Mode
PRR
Mode
SUB
Mode