097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 127
Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
Table 4-3. Alarm Conditions and Defaults
Alarm ID
Description of Alarm
Condition
Possible
Alarm
Levels
Error
Delay
Default
Error
Delay
Editable?
Default Level
SSU
Mode
SUB
Mode
<aid> = SYS
PWRA
Loss of A power
MN | MJ |
CR
IMMED
No
MJ
MJ
PWRB
Loss of B power
MN | MJ |
CR
IMMED
No
MJ
MJ
EXPFAIL
Connection to the
Expansion Panel is lost
NR | NA |
MN | MJ |
CR
IMMED
No
MJ
MJ
EXTALM
External alarm
generated by external
equipment
NR | NA |
MN | MJ |
CR
IMMED
No
MN
MN
<aid> = IMC
IOC1COMM
Comm alarm with IOC
1
NR | NA |
MN | MJ |
CR
IMMED
No
MN
MN
IOC2COMM
Comm alarm with IOC
2
NR | NA |
MN | MJ |
CR
IMMED
No
MN
MN
<aid> = IOC
IOC1COMM
Comm alarm from IMC
module to IOC1 module
NR | NA |
MN | MJ |
CR
IMMED
No
MN
MN
IOC2COMM
Comm alarm from IMC
module to IOC2 module
NR | NA |
MN | MJ |
CR
IMMED
No
MN
MN
IOC1TO2
COMM
Comm alarm from
IOC1 to IOC2
NR | NA |
MN | MJ |
CR
IMMED
No
MN
MN
IOC2TO1
COMM
Comm alarm from
IOC2 to IOC1
NR | NA |
MN | MJ |
CR
IMMED
No
MN
MN
IOCFAIL
Summary alarm of IOC
failures; for example,
calibration was unsuc-
cessful
MN | MJ |
CR
IMMED
No
MJ
MJ