097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 171
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
RESET
The indicated IOC is
being restarted after a
user-requested reset.
All alarms are cleared,
if it was Active, it
becomes Standby
EQPT
n/a
n/a
SYSMODE
The system mode of
operation has been
changed
EQPT
SSU
SSU – Sync Supply Unit
mode
SUB – Subtending mode
PRR – Primary Reference
Receiver mode
IOC Clock Events
CLKFSTLK
The local oscillator in
the specified IOC is in
Fast-Lock mode
EQPT
n/a
n/a
CLKLOCK
The local oscillator in
the specified IOC is in
Lock mode
EQPT
n/a
n/a
SCAVAIL
The specified IOC is in
SmartClock mode
EQPT
OFF
OFF – SmartClock is not
available
ON – SmartClock is available
IOC Input Events
CRCENA
Indicates whether the
E1 (CAS/CCS) inputs
are using CRC4
checking. If the E1
input is provisioned to
read SSMs, then this
value is Enabled
T1
DISABLE
ENABLE | DISABLE
Table 6-5. Event Codes (Continued)
Event ID
Keyword
Description
AID
TYPE
Default Value/
Keyword
Description of Values