72
SV 200A User Manual
If you click the
TRIGGER
button, the
TRIGGER
CONDITIONS
configuration box will pop-up.
In this box, you can add the condition type:
Threshold
,
Spectrum
,
Meteo
and
System
.
The
Threshold
condition can be of
Level+
or
Level-
type (
Mode
). The
condition is fulfilled during the
period in which the controlled
value of the selected result
(
Source
) will be higher/lower than
the
Threshold
level.
You can select as a
Source
different results (
Leq
,
Lpeak
,
Lmax
,
Lmin
, etc.) for
three profiles (
Pr 1
,
Pr 2
and
Pr 3
), measured by:
1s
, integration period (for
example,
1m, SR
) or time-history step (for example,
50, TH
).
In the right-hand example,
1m, SR
means that the Integration period for the
Summary results was set to 1 minute, while
50, TH
means that the Step for the
time-history was set to 50 milliseconds.
If you expand the
Threshold
by
clicking the
field, you
can define
Start
and
Stop
threshold
levels
and
delays
(
Min. duration
) of start and stop.
After confirmation (
OK
) the pop-up box closes, and the selection will be presented in the line of the
TRIGGER