YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL)
1B-9
ABNORMAL NOISE FROM CRANKSHAFT PULLEY
Condition
Possible Cause
Correction
A large rattling noise is heard at
idle or sudden acceleration.
Loosen pulley mounting bolt.
Worn or broken bearings.
Retighten bolt.
Replace bearings.
ABNORMAL NOISE FROM TENSION PULLEY
Condition
Possible Cause
Correction
Clattering noise is heard from
pulley.
Pulley cranks upon contact.
Worn or damaged bearings.
Cracked or loose bracket.
Replace bearings.
Replace or retighten bracket.
ABNORMAL NOISE FROM EVAPORATOR
Condition
Possible Cause
Correction
Whistling sound is heard from
evaporator.
Depending on the combination of
the interior / exterior
temperatures, engine rpm and
refrigerant pressure, the
refrigerant flowing out of the
expansion valve may, under
certain conditions, make a
whistling sound.
At times, slightly decreasing
refrigerant volume may stop this
noise.
Inspect expansion valve and
replace if faulty.
ABNORMAL NOISE FROM BLOWER MOTOR
Condition
Possible Cause
Correction
Blower motor emits a chirping
sound in proportion to its speed of
rotation.
Fluttering noise or large droning
noise is heard from blower motor.
Worn or damaged motor brushes
or commutator.
Leaves or other debris
introduced from fresh air inlet to
blower motor.
Repair or replace blower motor.
Remove debris and make sure
that the screen at fresh air inlet is
intact.
Summary of Contents for Grand Vitara 1998
Page 225: ...YH4 GRAND VITARA FRONT SUSPENSION 3D 23 TIGHTENING TORQUE SPECIFICATIONS ...
Page 531: ...YH4 GRAND VITARA 8 6 BODY ELECTRICAL SYSTEM POWER SUPPLY DIAGRAM Refer to Section 8A ...
Page 659: ...YH4 GRAND VITARA BODY SERVICE 9 41 1 Side body outer panel A Apply sealant B Brush treatment ...
Page 673: ...YH4 GRAND VITARA BODY SERVICE 9 55 B B C C 2 DOOR MODEL ...