YH4
GRAND
VITARA
1. Electric leak detector
AIR CONDITIONING (OPTIONAL)
1B-29
REMOVING MANIFOLD GAUGE SET
When A / C system has been charged with a specified amount of re-
frigerant, remove manifold gauge set as follows:
1) Close low pressure-side valve of manifold gauge set, (The high
pressure-side valve is closed continuously during the process
of charging.).
2) Close refrigerant container valve.
3) Stop engine.
4) Using shop rag, remove charging hoses from service valves.
This operation must be performed rapidly.
WARNING:
High pressure-side is naturally under high pressure.
So, care must be used to protect your eyes and skin.
5) Put caps on service valves.
LEAK-TESTING REFRIGERANT SYSTEM
Whenever a refrigerant leak is suspected in the system or any ser-
vice operation has been performed which may result in disturbing
lines or connections, it is advisable to test for leaks.
Common sense should be used in performing any refrigerant leak
test, since the need and extent of any such test will, in general, de-
pend upon the nature of a complaint and the type of a service per-
formed on the system.
LIQUID LEAK DETECTORS
There are a number of fittings and places throughout the air condi-
tioning system where a liquid leak detector solution may be used
to pinpoint refrigerant leaks.
By merely applying the solution to the area in question with a swab,
bubbles will form within seconds if there is a leak.
For confined areas, such as sections of the evaporator and con-
denser, an electronic (gas) leak detector is more practical for deter-
mining leaks.
WARNING:
To prevent explosions or fires, make sure that there are no
flammables in the vicinity.
When exposed to fire, the refrigerant turns into a poison-
ous gas (phosgene). Do not inhale this gas.
Summary of Contents for Grand Vitara 1998
Page 225: ...YH4 GRAND VITARA FRONT SUSPENSION 3D 23 TIGHTENING TORQUE SPECIFICATIONS ...
Page 531: ...YH4 GRAND VITARA 8 6 BODY ELECTRICAL SYSTEM POWER SUPPLY DIAGRAM Refer to Section 8A ...
Page 659: ...YH4 GRAND VITARA BODY SERVICE 9 41 1 Side body outer panel A Apply sealant B Brush treatment ...
Page 673: ...YH4 GRAND VITARA BODY SERVICE 9 55 B B C C 2 DOOR MODEL ...