YH4
GRAND
VITARA
HEATER AND VENTILATION
1A-13
1. Lever
FOR LEFT HAND STEERING VEHICLE
FOR RIGHT HAND STEERING VEHICLE
4) Disconnect heater mode control actuator coupler (1).
5) Disconnect heater mode control actuator rod (2) from heater
unit.
6) Remove heater mode control actuator from heater unit by re-
moving its mounting screw (3).
INSPECTION
1) Connect battery voltage (+) to terminal “b’” and (–) to terminal
“a”.
2) Connect each terminal listed below to terminal “a’” (negative (–)
terminal of battery) and check if lever rotation angle is as speci-
fied in figure.
MODE
TERMINAL
VENT
c
BI-LEVEL
d
HEAT
e
DEF / HEAT
f
DEF
g
INSTALLATION
1) Install in reverse order of removal procedure.
2) If equipped with air bag system, enable air bag system.