AIR CONDITIONING (OPTIONAL)
1B-47
DUAL PRESSURE SWITCH
INSPECTION
1) Check dual pressure switch (1) on liquid pipe for continuity at
normal temperature (approx. 25
_
C (77
_
F)) when A / C system
has a proper charge of refrigerant and when A / C system (com-
pressor) is under operation. In each of these cases, switch
should show proper continuity.
2) Using a manifold gauge set, check switch for operation at speci-
fied pressure as shown, refer to “PERFORMANCE DIAGNO-
SIS” in this section.
Switch ON
: above “C” and below “D”
Switch OFF : below “A” or above “B”
“A”: Approx. 200 kPa (2.0 kg / cm
2
)
“B”: Approx. 3200 kPa (32 kg / cm
2
)
“C”: Approx. 230 kPa (2.3 kg / cm
2
)
“D”: Approx. 2800 kPa (28 kg / cm
2
)
Tightening torque:
Dual pressure switch: 10 N
.
m (1.0 kg-m, 7.5 lb-ft)