YH4
GRAND
VITARA
1. Drain plug (Apply sealant)
2. Reverse idle gear shaft bolt (DO NOT LOOSEN IT)
3. Filler / level plug (Apply sealant)
1. Drain plug
2. Filler / level plug
Type 1
Type 2
1. Level gauge
2. FULL HOT mark
3. LOW HOT mark
4. FULL COLD mark
5. LOW COLD mark
0B-20
MAINTENANCE AND LUBRICATION
ITEM 6-10
Manual Transmission Oil Inspection and Change
Inspection
1) Inspect transmission case for evidence of oil leakage.
Repair leaky point if any.
2) Make sure that vehicle is placed level for oil level check.
3) Remove level plug of transmission.
4) Check oil level.
Oil level can be checked roughly by means of level plug hole.
That is, if oil flows out of level plug hole or if oil level is found up
to hole when level plug is removed, oil is properly filled.
If oil is found insufficient, pour specified amount of specified oil.
5) Tighten level plug to specified torque.
Refer to Section 7A or 7A1 for installation and tightening torque.
Change
Change transmission oil with new specified oil referring to Section
7A or 7A1.
ITEM 6-11
Automatic Transmission Fluid Inspection and Change
Inspection
1) Inspect transmission case for evidence of fluid leakage.
Repair leaky point, if any.
2) Make sure that vehicle is placed level for fluid level check.
3) Check fluid level.
For fluid level checking procedure, refer to On-vehicle service in
Section 7B1 and be sure to perform it under specified conditions.
If fluid level is low, replenish specified fluid.
Summary of Contents for Grand Vitara 1998
Page 225: ...YH4 GRAND VITARA FRONT SUSPENSION 3D 23 TIGHTENING TORQUE SPECIFICATIONS ...
Page 531: ...YH4 GRAND VITARA 8 6 BODY ELECTRICAL SYSTEM POWER SUPPLY DIAGRAM Refer to Section 8A ...
Page 659: ...YH4 GRAND VITARA BODY SERVICE 9 41 1 Side body outer panel A Apply sealant B Brush treatment ...
Page 673: ...YH4 GRAND VITARA BODY SERVICE 9 55 B B C C 2 DOOR MODEL ...