YH4
GRAND
VITARA
HEATER AND VENTILATION
1A-11
1
1. Mode control switch coupler
7) Disconnect heater blower motor switch connector (1).
8) Remove mode control switch with heater control lever assem-
bly from the removed hole in mentioned step (5).
9) Pull off heater control lever knob.
10) Remove heater mode control switch (2) with heater control
panel (3) from heater control lever assembly (1).
11) Remove heater control panel from mode control switch.
INSPECTION
Mode Control Switch
Check if continuity exists between each pair of terminals listed be-
low when mode control button is pressed.
Mode
Mode control switch terminals
VENT
F – M
BI-LEVEL
F – N
HEAT
F – E
DEF / HEAT
F – B
DEF
F – C
With battery voltage (+) connected to terminal “I” and (–) to termi-
nal “F”, press each mode control button and check if indicator
lamp (3) lights.
With battery voltage (+) connected to terminal “A” and (–) to termi-
nal “H”, check if illumination lamp lights.
Summary of Contents for Grand Vitara 1998
Page 225: ...YH4 GRAND VITARA FRONT SUSPENSION 3D 23 TIGHTENING TORQUE SPECIFICATIONS ...
Page 531: ...YH4 GRAND VITARA 8 6 BODY ELECTRICAL SYSTEM POWER SUPPLY DIAGRAM Refer to Section 8A ...
Page 659: ...YH4 GRAND VITARA BODY SERVICE 9 41 1 Side body outer panel A Apply sealant B Brush treatment ...
Page 673: ...YH4 GRAND VITARA BODY SERVICE 9 55 B B C C 2 DOOR MODEL ...