Chapter 8
Motherboard and Component Replacement
8-19
1. Using long-nose pliers, set the motherboard serial port jumpers JP3 and JP4 (refer
to the following table).
Note –
Motherboard jumpers are identified as JP. Jumper pins are located
immediately adjacent to the part number.
FIGURE 8-9
Identifying Jumper Pins
2. Replace the motherboard as follows (
and
):
a. Replace the motherboard as follows:
Caution –
Handle the motherboard by the back panel or the edges only.
i. Position the motherboard into the chassis.
ii. Using a No. 2 Phillips screwdriver, replace the seven screws securing the
motherboard to the chassis (including the CPU standoff screw).
iii. Connect the external cables.
b. Replace the following:
i. PCI riser board and support
TABLE 8-2
Serial Port Jumper Settings
Jumper
Pins 1 + 2 Select
Pins 2 + 3 Select
Default Shunt
on Pins
JP3
RS-232
RS-423
2-3
JP4
RS-232
RS-423
2-3
Closed
Open
2-3
1
1-2
1
Summary of Contents for Ultra 5
Page 12: ...xii Sun Ultra 5 Service Manual February 2000...
Page 46: ...1 8 Sun Ultra 5 Service Manual February 2000...
Page 72: ...3 24 Sun Ultra 5 Service Manual February 2000...
Page 102: ...4 30 Sun Ultra 5 Service Manual February 2000...
Page 112: ...5 10 Sun Ultra 5 Service Manual February 2000...
Page 168: ...8 22 Sun Ultra 5 Service Manual February 2000...
Page 186: ...A 10 Sun Ultra 5 Service Manual February 2000...
Page 246: ...D 6 Sun Ultra 5 Service Manual February 2000...