Chapter 7
Storage Devices
7-15
4. Verify that the replica was deleted using the
metadb
command again:
5. Reboot the system.
6. Halt the system and replace the failed hard drive (refer to Section 7.2 “Hard
7. After replacing the failed hard drive, power on and reboot the system.
8. Use the
format
or the
fmthard
command to partition the hard drive as it was
before the failure. Using the example, you would type:
9. Use the
metadb
command to add back the state database replicas and to
determine that the state database replicas are correct. Using the example, you
would type:
# usr/opt/SUNWmd/metadb -i
flags first blk block count
a m p lu 1050 1034 /dev/dsk/c0t3d0s3
# halt
ok boot
# format /dev/rdsk/c1t2d0s0
# usr/opt/SUNWmd/metadb -a /dev/dsk/c1t2d0s3
flags first blk block count
a m p luo 16 1034 /dev/dsk/c0t3d0s3
a u 16 1034 /dev/dsk/c1t2d0s3