Chapter 4
Maintaining the Sun Fire X2100 M2 Server
4-39
Caution –
The heatsink can become extremely hot. Be sure it has had sufficient time
to cool before handling.
4. Twist the heatsink slightly to the right or left to break the seal with the thermal
grease.
5. Lift the heatsink away from the CPU.
6. Place the heatsink upside-down on a flat surface to prevent the thermal grease
from contaminating other components.
7. Pull the socket release lever up to the fully open, perpendicular position.
8. Open the CPU cover.
FIGURE 4-33
Removing the CPU
9. Lift the CPU out of the socket, leaving the release lever in the open position.
Note –
Ensure that no thermal grease that might be left from the heatsink comes
into contact with the CPU socket or underside of the CPU chip.