4-14
Sun Fire X2100 M2 Server Service Manual • December 2006
2. Grasping the body of the drive in both hands, carefully guide the connector end
of the carrier into the drive bay, sliding the carrier into the bay until the arm
engages and partially closes itself.
3. Push the arm forward and latch it to lock the carrier in place.
4.5.4
Installing an LSI PCIe Card and Cables
This section contains instructions on installing and LSI PCIe card. This card enables
the following added functionality for the Sun Fire X2100 M2 server:
■
Standalone SAS hard drive support
■
RAID support using SAS hard drives
■
RAID support using SATA hard drives
Use the appropriate procedure, depending on the hard drive format that you are
using:
■
“Installing the LSI Card to Support SAS Hard Drive Installation” on page 4-14
■
“Installing the LSI Card to Support SATA RAID” on page 4-17
4.5.4.1
Installing the LSI Card to Support SAS Hard Drive
Installation
If your system originally had SATA drives installed or came diskless, and you would
like to install SAS drives, use the following procedure.
You will need to order the following components needed for the SAS drive
installation:
■
An LSI PCIe card
■
One or two SAS HDDs
The following procedure describes how to remove the current SATA installation and
install the SAS components. If you started with a diskless system, you do not need
to do Step 2.
1. Power off the system and remove the cover as described in
Section 4.3, “Powering
Off the Server and Removing the Cover” on page 4-3
.
2. Remove the current SATA hard drive(s) from the server, if necessary.
See
Section 4.5.3.1, “Removing an HDD and Carrier” on page 4-12
.
Summary of Contents for Sun Fire X2100 M2
Page 46: ...3 20 Sun Fire X2100 M2 Server Service Manual December 2006 ...
Page 94: ...4 48 Sun Fire X2100 M2 Server Service Manual December 2006 ...
Page 98: ...A 4 Sun Fire X2100 M2 Server Service Manual December 2006 ...
Page 123: ...Appendix C Installing the Server Into a Rack With Optional Slide Rails C 15 ...
Page 124: ...C 16 Sun Fire X2100 M2 Server Service Manual December 2006 ...
Page 128: ...Index 4 Sun Fire X2100 M2 Server Service Manual December 2006 ...