Chapter 4
Maintaining the Sun Fire X2100 M2 Server
4-31
4.5.10
Replacing Memory Modules
The following procedure describes how to remove and or install dual inline memory
modules (DIMMs).
4.5.10.1
DIMM Population Rules
Note –
Keep in mind the following information and rules when you use the
procedures in this section to replace or add DIMMs to the server.
■
Four unbuffered DDR2 DIMMs are supported.
■
DIMM 0 is farthest from the CPU.
■
Populate the slots in order from slot 0 to slot 3.
4.5.10.2
Removing a DIMM
To remove a DIMM:
1. Power off the system and remove the cover as described in
Section 4.3, “Powering
Off the Server and Removing the Cover” on page 4-3
.
2. Locate the DIMM connector in which you will install or replace a memory
module.