4-8
Sun Fire X2100 M2 Server Service Manual • December 2006
4.5.1.2
Installing the I/O Board
To install the I/O board:
1. Position the I/O board on top of the HDD cage so the openings on the board line
up with the guides on top of the HDD cage.
FIGURE 4-4
Installing the I/O Board
2. Gently push the I/O board down to engage the guides and push the board
forward to secure it.
3. Fasten the screws to secure the I/O board to the mounting bracket.
4. Reconnect the cables.
5. Before reinstalling the cover on the server, check the routing of all cables for
obstructions.