4-18
Sun Fire X2100 M2 Server Service Manual • December 2006
FIGURE 4-14
SATA Drive Cable Routing
3. Remove the riser assembly from the server. See
Section 4.5.2.1, “Removing the
Riser Assembly and PCIe Card” on page 4-9
.
4. Install the LSI PCIe card into the riser assembly. See
Section 4.5.2.2, “Installing the
PCIe Card and Riser Card Assembly” on page 4-10
.
Do not install the riser card into the server yet. It will be easier to connect the cables
with the card outside of the system.
5. Connect the SATA cables to the LSI PCIe card connectors. See
FIGURE 4-13
.
■
Connect the red cable to PHY 0.
■
Connect the blue cable to PHY 1.