A-2
Sun Fire X2100 M2 Server Service Manual • December 2006
A.2
Power Specifications
Power specifications for Sun Fire X2100 M2 server are as follow:
■
Single power supply
■
UL maximum (AC input) 6.5 amps
■
Power supply rating (max. DC output) 345 W
A.3
Environmental Specifications
Environmental specifications for the Sun Fire X2100 M2 server are shown in
TABLE A-2
.
.
TABLE A-2
Sun Fire X2100 M2 Server Environmental Specifications
Specification
State
British
Metric
Humidity
Operating
7%–93% RH non-
condensing, 80.6˚ F
max wet bulb
7%–93% RH non-
condensing, 38˚ C
max wet bulb
Nonoperating
93% RH, non-
condensing, 100.4˚ F
max wet bulb
93% RH, non-
condensing, 43˚ C
max wet bulb
Vibration
Operating
0.12 G x-y, 0.17 G z;
5–500 Hz sine
Nonoperating
0.3 G x-y, 0.6 G z;
5–500 Hz sine
Shock
Operating
4.5 G to 3.5 G;
11 msec. half-sine
Temperature
Operating
36˚ F to 100˚ F
2˚ C to 38˚ C
Nonoperating
-40˚ F to 154˚ F
-40˚ C to 68˚ C
Maximum operating
temperature
derating
-1.8˚ F for every 985
ft. in altitude
-1˚ C for every 300
m in altitude
Altitude
Operating
max 9,843 ft
max 3,000 m
Summary of Contents for Sun Fire X2100 M2
Page 46: ...3 20 Sun Fire X2100 M2 Server Service Manual December 2006 ...
Page 94: ...4 48 Sun Fire X2100 M2 Server Service Manual December 2006 ...
Page 98: ...A 4 Sun Fire X2100 M2 Server Service Manual December 2006 ...
Page 123: ...Appendix C Installing the Server Into a Rack With Optional Slide Rails C 15 ...
Page 124: ...C 16 Sun Fire X2100 M2 Server Service Manual December 2006 ...
Page 128: ...Index 4 Sun Fire X2100 M2 Server Service Manual December 2006 ...