4-20
Sun Fire X2100 M2 Server Service Manual • December 2006
4.5.5.1
Removing an ODD Drive Assembly
To remove an ODD (DVD or CD) drive assembly:
1. Power off the system and remove the cover as described in
Section 4.3, “Powering
Off the Server and Removing the Cover” on page 4-3
.
2. Unfasten the drive ribbon cable from the
ODD
drive.
Caution –
Use care with the small flat cables. They are extremely fragile.
FIGURE 4-16
Removing the DVD Drive Assembly
3. Push the latch on the back of the
ODD
drive toward the drive until the
ODD
drive
springs forward out of the chassis.
4. Pull the
ODD
drive out the front of the chassis.
Caution –
Move the assembly by grasping it by its sides. Do not push on the
DVD-ROM tray.