Chapter 3
Performing Diagnostics
3-9
To load one of the scripts available to test the devices on your system, do the
following:
●
From the main menu, choose Immediate Burn-in Testing.
The top portion of the window lists the options described in
TABLE 3-3
, and the
bottom portion of the window lists the following Burn-in menu options:
■
Load Burn-in Script
Enter one of the following:
■
quick.tst
,
noinput.tst
, or
full.tst
■
If you have created and saved your own script, enter
d:\
testname
.tst
Where
testname
is the name of the script that you have created.
■
Save Burn-in Script
To save a burn-in script that you have created, enter
d:\
testname
.tst
Where
testname
is the name of the script that you have created.
■
Change Options
Opens the Burn-in Options menu, which enables you to modify the various
options listed in
TABLE 3-3
for the currently loaded test script.
■
Select Tests
Opens a listing of the tests available for your server configuration and the
currently loaded test script.
■
Perform Burn-in Tests
Runs the currently loaded burn-in test script.
3.5
Deferred Burn-in Testing
You can use the Deferred Burn-in Testing option to create and save your own scripts
to run at a later time.
●
From the main menu, choose Deferred Burn-in Testing.
The top portion of the window lists the options described in
TABLE 3-3
, and the
bottom portion of the window lists the following Burn-in menu options:
■
Load Burn-in Script
Enter one of the following:
■
quick.tst
,
noinput.tst
, or
full.tst
■
If you have created and saved your own script, enter
d:\
testname
.tst
Where
testname
is the name that you have created.
Summary of Contents for Sun Fire X2100 M2
Page 46: ...3 20 Sun Fire X2100 M2 Server Service Manual December 2006 ...
Page 94: ...4 48 Sun Fire X2100 M2 Server Service Manual December 2006 ...
Page 98: ...A 4 Sun Fire X2100 M2 Server Service Manual December 2006 ...
Page 123: ...Appendix C Installing the Server Into a Rack With Optional Slide Rails C 15 ...
Page 124: ...C 16 Sun Fire X2100 M2 Server Service Manual December 2006 ...
Page 128: ...Index 4 Sun Fire X2100 M2 Server Service Manual December 2006 ...