Operating instruction Z7510 Multizone temperatur controller
I
Temperatur controller
64
STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de
08.2018
Operations manual NR4000-v.2
64
- Ser. interface -
Standard
STRACK STRACK
protokol pre-set
:
standard
protokol
- ARBURG
ARBURG / ENGEL or
all other injection mould
-
ing machines with
„HB-Therm“ protocol
- Gateway
Protokol valid
for InterBus-S.
Only with RS 485-
interface
- Ser. interface
1 .... 255
(
factory default: 1
)
Device adress :
This is the adress a master device communicates
with the controller. Each ontroller must have ist
own adress. Max. 32 controllers can be
connected to a RS485-bus.
- Ser. interface
Data format :
7 data bit, even parity,
1 stop bit
(
factory default
)
7 data bit, odd,
1 stop bit
7 data bit, even,
2 stop bit
7 data bit, odd,
2 stop bit
7 data bit, no,
2 stop bit
8 data bit, even,
1 stop bit
8 data bit, odd,
1 stop bit
8 data bit, no,
1 stop bit
(Gateway)
8 data bit, no,
2 stop bit
- Ser. interface
Baudrate :
off; 0,3 ... 9,6 kBaud
(
factory default: 9,6
)
InterBus-S Gateway = 9,6 kBaud