Operating instruction Z7510 Multizone temperatur controller
I
Temperatur controller
11
STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de
08.2018
Operations manual NR4000-v.2
NOLDEN Regelsysteme GmbH
11
Maximum load capacity for the heater when using
mould connector VK24 (24-pol. + PE) or VK16 (16-pol.
+ PE)
The maximum load capacity of the heater wires
(1,5sqmm Cu) depends on the operating conditions (see
also DIN VDE 0298 Part 2 and 4).
@ op. condition :
Continuous
@ wire location :
Individually, free installation on wall
or floor
@ ambiant
Temperature :
30°C, free air circulation, no heat
radiation
VK 24 :
VK 16 :
1 heater
12,5 A
1 heater
12,5 A
2 heaters
12,5 A
2 heaters
12,5 A
3 heaters
11,5 A
3 heaters
11,5 A
4 heaters
10,5 A
4 heaters
10,5 A
5 heaters
10,0 A
6 heaters
9,5 A
Load and TC-
connection NR24 :
Load and TC-
connection NR16 :
Other pin assignment
(see appendix chapter 8.1 of this manual)