Operating instruction Z7510 Multizone temperatur controller
I
Temperatur controller
41
STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de
08.2018
Operations manual NR4000-v.2
NOLDEN Regelsysteme GmbH
41
- Softstart :
Range : Setpoint min.....
setpoint
(°C)
setpoint max.
(
factory default : 80
)
- Softstart :
off; 0,1... 10,0 min.
duration time (min.)
(
factory default : 5,0
)
General remarks about softstart :
Setpoint 1
Softstart-
Setpoint
Softstart-output ratio Softstart-
Duration time
During the softstart, the controllers output response
is limited to a preselected
softstart output ratio
in order to achieve a slow baking out of high perfor-
mance heating cartridges. Once the process value
reaches the
softstart setpoint
, it remains stable at
this value for a preselected
softstart duration time
.
At the end of this period, the process value rises to
the assigned setpoint.