Operating instruction Z7510 Multizone temperatur controller
I
Temperatur controller
10
STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de
08.2018
Operations manual NR4000-v.2
10
4. Installation and wiring :
4.1 Installation :
The installation site must provide easy access for
the operator without hazard. Sufficient mechanical
stability must be guaranteed, also secure the device
from slipping on the installation surface.
Protect from heat, radiation and allow free air circu-
lation. Protect power cable from heat and mechani-
cal stress. Do not place the device on hot surfaces.
Take care of the tension load created by the wiring,
fix the cables separately from the controller.
4.2 Connection of the power supply :
This device must only be operated at the voltage
indicated on the name plate. Please check for a
sufficient fuse protection of the power outlet fore-
seen for the device.
Protective earth conductor must be provided !
4.3 Connection of heater and thermocouples :
Please compare the connecting diagram on the
temperature controller (backside, near the outlet)
with the diagram of the mould. Inappropriate con
nection can destroy controller, heater and TC !
Available mould connecting cables contain heater–
and FeCu-Ni compensation wires for TC. Never use
compensation wires to connect a heater.