Operating instruction Z7510 Multizone temperatur controller
I
Temperatur controller
56
STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de
08.2018
Operations manual NR4000-v.2
56
2. Zone configuration
Parameter
Setting
- Zone 1-8 on / off
on
- Controller output mode
Automatic
- Setpoint2
100°C
- Boost addition
5°C
- Boost holding time
30 sec.
- Softstart
on
- Softstart output ratio
50%
- Softstart setpoint
80°C
- Softstart duration time
5 min
- Setpoint limitation max.
400°C
- Setpoint limitation min.
0°C
- Copy all parameters to
off
- Max. output ratio limit
100%
- Ramp rising
off
- Ramp falling
off
- Proportional band
6,0%
- Rate time
30 sec.
- Reset time
150 sec.
- Process offset
off
- Sensor configuration
TC Fe-CuNi (J) 0 - 400°C