187
Commissioning
1.
Set the pressure adjust-
ment button to minimum
pressure.
2.
Switch the device on (ON).
3.
Increase the pressure by
half to start the motor and
allow the fluid to circulate
for 15 seconds through the
bypass pipe; then reduce
the pressure again.
4.
Set the bypass switch to
the SPRAY position. Set
the trigger lock on the
spray gun to OFF.
5.
Hold the spray gun against
an earthed rinsing contai-
ner. Press the trigger and
turn the pressure regulator
clockwise through a half
rotation.
6.
Make sure that threaded
joints are tight. Do not
attempt to seal leaks with
your hand or a rag. In case
of leaks, relieve the pres-
sure immediately. Tighten
the threaded joints firmly
and avoiding leaks. Per-
form steps 1. - 5. of com-
missioning. If not leaks
occur, continue with step
6.
7.
Place the siphon tube in
the paint container.
8.
Actuate the spray gun,
while pointing it into the
rinsing container, until
paint is sprayed. Point the
spray gun into the paint
container and actuate
for 20 seconds. Lock the
trigger lock (ON). Fit the
tip and tip guard; see the
instructions on the next
page.
Original instruction
Summary of Contents for Airless SL 1600 HD
Page 1: ...Airless SL 1600 HD SL 1600 HD Plus DE NL FR IT GB CZ...
Page 31: ...31 Steuerung bersetzung der Originalanleitung...
Page 33: ...33 Farbstufe bersetzung der Originalanleitung...
Page 75: ...75 Besturing Vertaling van de originele handleiding...
Page 77: ...77 Verftrap Vertaling van de originele handleiding...
Page 119: ...119 Commande Traduction des instructions d origine...
Page 121: ...121 Nuancement des couleurs Traduction des instructions d origine...
Page 163: ...163 Comando Traduzione delle istruzioni originali...
Page 165: ...165 Stadio di colore Traduzione delle istruzioni originali...
Page 207: ...207 Control unit Original instruction...
Page 209: ...209 Paint stage Original instruction...
Page 251: ...251 zen P eklad origin lu n vodu...
Page 253: ...253 Barevn stupe P eklad origin lu n vodu...
Page 266: ...266...
Page 267: ...267...